Description
Features
- Detects X,γ radiation and measures personal cumulative dose equivalent H (10)
- Personal dose equivalent rate Hp (10)
- LCD display shows dose and dose rate
- User can switch between dose and dose rate modes using a button
- Three preset dose rate alarms and one preset cumulative dose alarm
- Light, sound, and LCD display alarm when any threshold is exceeded
- Automatic data storage during detection
- Data can be read during standby mode and persists even after power failure
- Alerts user with sound and light when dose increases
- Built in rechargeable Li battery
- Easy to use, suitable for both professional and personal use
- Provides timely radiation detection and safety warnings
Technical Specifications
Detector | Semiconductor detector |
Detect Range | Dose rate: 1 mSv per h to 1 Sv per h;Cumulative dose: 0.01 mSv to 10 mSv |
Alarm Threshold | Dose rate threshold:0.5 mS v per h, 2.5 mS v per h, 10 m Sv per h; Cumulative dose threshold: 1 mS v; Dose increase prompt value:1 mS v; Above value also can be set according to customer. |
Power Source | Rechargeable lithium battery 3.6 V. One full charge may work 200 hours. |
Low Battery Indication | More than 8 hours can last when under-voltage alarm |
Energy Response | < ± 30 % (50 ke V to 1.5 Me V) |
Dose Response Linear | < ± 20 % (0.1 mSv per h to 1 Sv per h) |
Relative Intrinsic Error | < ± 10 % (1.5 mSv per h) |
Temperature | < ± 15 %, -50 °F to +104 °F (-10 ℃ to + 40 ℃) |
Humidity Effect | < ± 10 % RH, 40 % RH to 90 % RH 95 °F (35 ℃) |
Dimensions | 2.05 in x 1.57 in x 0.55 in (52 mm x 40 mm x 14 mm) |