Description
Features
- Frequency Range: 9 kHz to 1.5 GHz
- DANL (Displayed Average Noise Level): -160 dBm
- Phase Noise: -80 dBc/Hz @1GHz, 10 kHz offset
- Total Amplitude Accuracy: <0.7 dB
- Resolution Bandwidth (RBW): 1 Hz minimum
- EMI Pre-compliance: Optional kit, EMC test software
- Tracking Generator: Optional, remotely upgradeable
- Advanced Features: Waterfall plot, modulation analysis, audio demodulation
- Pass or Fail Test: Standard on-site with alert function
- Digital Intermediate Frequency Technology: All-digital IF
- Interfaces: USB Host, USB Device, LAN, earphone, HDMI
- Display: 9 in (22.86 cm) LCD, 1280×800 pixels
Â
Technical Specifications
Frequency Range | XSA805(TG): 9 kHz to 500 MHz XSA810(TG): 9 kHz to 1 GHz XSA815(TG): 9 kHz to 1.5 GHz |
Frequency Resolution | 1 Hz |
Reference Frequency Aging Rate | <1 ppm per year |
Frequency Span | Span Range: 0 Hz, 100 Hz to max frequency of the instrument Span Uncertainty: ±span or (sweep points 1) |
SSB Phase Noise (fc = 500 MHz) | 10 kHz: <-80 dBc/Hz100 kHz: <-100 dBc/Hz
1 MHz: <-115 dBc/Hz |
Resolution Bandwidth (-3 dB) | 1 Hz to 1 MHz, in 1-3-5-10 sequence |
RBW Accuracy | <5% typical |
Video Bandwidth (-3 dB) | 10 Hz to 1 MHz, in 1-3-5-10 sequence |
Amplitude Measurement Range | DANL to +10 dBm, 100 kHz to 10 MHz, Preamp Off DANL to +20 dBm, fc ≥ 10 MHz, Preamp Off |
Reference Level | -80 dBm to +30 dBm, 0.01 dB by step |
Preamp | 20 dB, nominal, 100 kHz to 1.5 GHz |
Input Attenuator | 0 dB to 40 dB, 1 dB by step |
Display Average Noise Level | Preamp Off: -95 dBm to -140 dBm (Typical) Preamp On: -135 dBm to -160 dBm (Typical) |
Level Display | Trace Detectors: positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak |
Frequency Response (fc ≥100 kHz) | Preamp Off: <0.7 dB Preamp On: <1.0 dB |
Uncertainty | <0.4 dB (fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB) |
Level Measurement Uncertainty | <0.7 dB (95% confidence level, S/N >20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB) |
Tracking Generator (Optional) Frequency Range | XSA805(TG): 100 kHz to 500 MHz XSA810(TG): 100 kHz to 1 GHz XSA815(TG): 100 kHz to 1.5 GHz |
Tracking Generator (Optional) Output Power Level Range | -40 dBm to 0 dBm |
Tracking Generator (Optional) Output Level Resolution | 1 dB |
Tracking Generator (Optional) Output Flatness (Relative to 50 MHz) | ±3 dB |
Tracking Generator Spurious | Harmonic Spurious: -30 dBc (Tracking generator output power -10 dBm)Non-harmonic Spurious: -40 dBc (Tracking generator output power -10 dBm) |
Tracking Generator to Input Terminal Isolation | -60 dB (Tracking generator output power 0 dBm) |
Interface | USB Host, USB Device, LAN, earphone interface, HDMI |
Display | 9 in (22.86 cm) TFT LCD, 1280 x 800 pixels |
Dimension | 14.76 in x 7.25 in x 4.72 in (375 mm × 185 mm × 120 mm) |
Weight | Approx. 8.15 lb (3.7 kg) (main device) |