Description
Features
- One Function Key
- Easily Operate
- Ideal Menu Style
- Auto Calibration: Velocity, Probe Delay, Angle/K Value
Technical Specifications
Parameter | Value |
Measuring Range | 0.04 in to 472.44 in (1.0 mm to 12000 mm) |
Resolution | 0.0004 in (<3.94 in) (0.01 mm (<100 mm)), 0.04 in (>3.94 in) (1 mm (>100 mm)) |
Velocity | 500 m/s to 20000 m/s, 20 fixed velocities |
Delay | -20 µs to 3400 µs /resolution: 0.1 µs |
Probe Delay | 0 µs to 99 µs /resolution: 0.01 µs |
Auto Calibration | Velocity Calibration & Probe Delay Calibration |
Linear Error | Horizontal error ≤0.1%, Vertical error ≤3% |
Dynamic Range | ≥36 dB |
Sensitivity | ≥64 dB 200 mm Ф2 flat-bottomed hole |
Pulse | Dive Pulse, Negative spikes, high energy/low adjustable |
Launch Repetition Frequency | PFR transmit pulse continuously adjustable |
Matched Damp | 50 Ω or 150 Ω or 400 Ω |
Receiver | Measuring mode: Peak/Verge, Bandwidth: 0.3 to 1 MHz or 0.5 to 4 MHz or 2 MHz to 15 MHz |
Detector Pattern | 0 dB to 110 dB, 0/0.1/0.2/0.5/1/2/6/12/RF/Full-Wave/Positive/Negative/half-wave |
Display | LCD TFT Color Display 5 options for variable brightness |
GUI Theme | Simple/Classical/Gray/Bright |
Screen Update Rate | ≥60 Hz |
Gate / Measuring Value / Alarm | Sluice gate, Two Separated Gate A/B, Measured value display |
Storage | Channel Parameters: 20 groups, Scan A: 2000, Thickness values: 200,000 data, liner |
Input / Output | Probe connector: LEMO or BNC, Communication: RS232 |
Regional | Clock: date and time, Language: English, Unit: mm/inch |
Battery | Battery: High-energy lithium batteries, excellent overcharge and over-discharge protection |
Battery Monitoring | Coulomb energy measurement based on battery monitoring, the percentage/time display the remaining battery life |
Working Hours | Work continuously for more than 10 hours |
Battery Adapter | Input: 100 Hz to 240 Hz or 50 Hz to 60 Hz, Output: 9 V DC/4 A |
High Ranking | U disk storage, Storage screenshots/waveform/thickness three data report |
Gate Broadening | Gate area of concern for the details of observation and analysis |
B-scan Two-dimensional Coding | Thickness/contour scanning; grayscale/color palette settings |
Curve Freeze | YES |
Characteristic Indicator | Sound path measurement wave front and amplitude measurement position indicator |
CSC Surface Correction | According to probe angle, diameter of the work piece thickness and curvature correction for the measured values |
Lock | Each menu can be locked independently to avoid system-related parameter adjustment; data set can also be locked to avoid accidental deletion of data |
Screen Saver | Standby/Text/off |
Equivalent Curve | DAC curve, can record 30 calibration points; Automatic Gain; any order calibration; calibration/edit two modified methods; consider the material attenuation and surface compensation factor; five adjustable gain curves to assess compliance with JIS and API Standards |
DGS Curve | For large flat-bottomed, flat-bottomed hole via three reference types, consider a reference attenuation, attenuation, and surface material compensation factors, defect assessment methods: equivalent size/equivalent gain/percentage |
Standard | Main engine: 1, Straight/angle probe: 2, Probe line: 1, Charger: 1, Battery: 1 |
Working Environment | Temperature: -4 °F to 158 °F (-20 °C to 70 °C) |
Humidity | 5% to 90% |
Dimension (mm) | 9.45 in x 7.09 in x 1.97 in (240 mm × 180 mm × 50 mm) |
Weight | 4.19 lb (1.9 kg (including battery pack)) |