Description
Features
- QUALITY ASSURANCE
- 320 X 480 3.5 in (8.89 cm) LCD
- Test objects: ADSL, ADSL2, ADSL2+, READSL, VDSL2
- DURABLE
- Fast Copper tests with DMM (ACV, DCV, Loop
- Insulation Resistance, Capacitance, Distance)
- Support VLAN, Vectoring, Compliant with all known DSLAMS
- WIDE RANGE
- Supports Modem emulation and simulating login to Interne
- Supports ISP login (username or password)
- IP Ping test (WAN PING Test, LAN PING Test)
- Rechargeable Li-ion Battery
- Support optical power meter, VFL function
- Support cable tracing, check line sequence, landline telephone function
- Support cable fault locator (TDR) function
Technical Specification
Standards | ITU G.994.1 (G. hs), ITU G.992.5, ITU G.992.5 Annex L. The max distance which can be connected is mi (6.5 km), Be compatible with ADSL, ADSL2 and READSL. |
Attenuation | 0 dB to 63.5 dB |
Noise margin | 0 dB to 32 dB |
Upstream Channel Rate (interweaved or fast mode) | 0 Mbps to 1.2 Mbps |
Downstream Channel Rate (interweaved or fast mode) | 0 Mbps to 24 Mbps |
The modulating bits in the DMT sub-channel | 0 to 15 and each sub-channels’ frequency points |
The number of error codes | CRC, HEC, FEC, NCD, OCD |
Standards | ITU G.993.2 (VDSL2). Be compatible with ADSL2+, ADSL standard. |
Upstream Channel Rate (interweaved or fast mode) | 0 M to 100 M |
Downstream Channel Rate (interweaved or fast mode) | 0 M to 100 M |
The modulating bits in the DMT sub-channel | 0 to 15 and each sub-channels’ frequency points |
The number of error codes | CRC, HEC, FEC, NCD, OCD |
Support profiles | Profile 8 a, 8 b, 8 c, 8 d, 12 a, 12 b, 17 a, 30 a (optional), 35 b (optional) |
DC Voltage | -400 V to 400 V; Resolution: 0.1 V |
AC Voltage | 0 V to 290 V |
Capacitance | 0 nF to 1000 nF; Accuracy: 0 nF to 10 nF: ±2 nF, 10 nF to 1000 nF: ±2% ± 2 nF |
Loop Resistance | 0 KΩ to 20KΩ; Accuracy: 0 KΩ to 100 KΩ: ±3 % ± 4 Ω, 100 Ω to 500 Ω: ±3%, 500 KΩ to 20 KΩ: ±2% |
Insulation Resistance | 0 to 50 MΩ; Accuracy: 0 m to 1.0M: ± 0.1 MΩ, 1.0 M to 30 M: ±10% ±0.5 MΩ |
Test Range | 2.4 mi (4 km) (4.9 mi (8km) is optional) |
Highest resolution | 3.2 ft (1 m) |
Power consumption | 1 W |
VOP Adjusting range | 0.06 mi or 0.18 mi (100 m or us to 300 m or us) |
Distance test accuracy | 3.2 ft (1 m) |
Pulse test voltage range | 30 V |
Test cable type | Network cable, twisted pair cable, telephone line, USB cable, coaxial cable. |
Line status test | Determine open or short circuit |
Voltage polarity detection | Positive and negative of DC voltage |
Distance of signal transmission | No less than 1.8 mi (3 km) |
DC Voltage | No more than 48 V |
Wavelength range | 800 nm to 1700 nm |
Photo sensing material | In GaAs |
Power test range | -70 dBm to +10 or -50 dBm to +26 dBm |
Error range | ±5% |
Display distinguishability | Linear display: 0.1%; logarithmic display: 0.01 dBm |
 Adapters | 0.09 in (2.5 mm) universal adapter |
VFL | FP-LD |
Wavelength | 650 nm ± 20 nm |
Output power | 5 mw (10 mw or 20 mw optional) |
Connector | 0.09 in (2.5 mm) universal adapter |
Working mode | CW or 2 Hz modulation |
Applicable fiber | SM or MM |
Single gross weight | 3.3 lb (1.5 kg) |