Description
Features
- Compact and portable
- User-friendly interface
- Accurate measurements
- Fast operation
Â
Technical Specifications
Use | Fiber optic testing machine |
Product Name | OTDR |
Connector Type | FC/UPC (PC, APC optional) |
Display | 4.3 in touch screen, TFT 800×480 resolution |
VFL | 10 mW, CW/2Hz (10mW in default) |
OPM Range | Option A: +10 dBm to –70 dBm; Option B: +23 dBm to –50 dBm (option A in default) |
Battery | 5200 mAh/ 3.7 v |
Power Adapter | Power supply AC/DC adapter, input 100 to 250 V AC, 50 to 60 Hz, 3 A max, output 12 V DC, 35 W |
Data Storage | 100,000 Groups of curves |
Interface | USB A type x 1, micro-USB x 1, SD card |
Laser Source | Output power: -5dBm, modulation frequency: CW/270Hz/1KHz/2KHz |
Network Cable Test | Support network wire sequence testing and wire alignment |
Dynamic Range(dB) | 22 dB to 26 dB |
Loss Resolution(dB) | 0.001 |
Loss Threshold | 0.01 |
Attenuation Dead Zone(M) | 29.5 ft (900 cm) |
Distance Accuracy | ± (1.64 ft + range × 3 × 10^-5 + sampling resolution) (excluding refractive index error) |
Minimum Sampling Resolution | 0.65 ft (0.2m) |
Testing Distance | 328 ft, 1640ft, 1.24 mi, 3.1 mi, 6.2 mi, 12.4 mi, 24.8 mi, 49.7 mi, 55.9 mi (100 m, 500 m, 2 km, 5 km, 10 km, 20 km, 40 km, 80 km/ 90 km) |
Sampling Point | 64,000 |
Linearity | ≤0.05 dB/dB |
Distance Resolution | 0.03 ft (0.01 m) |
Working Temp | 14 °F to 122 °F (-10 °C to 50 °C) |
Storage Temp | -4 °F to 176 °F (-20 °C to 80 °C) |
Humidity | ≤95% (non-condensation) |
Dimension | 6.9 in x 4.1 in x 1.8 in (17.5 cm x 10.5 cm x 4.5 cm) |
Weight | 38.8 oz. including battery (1.1 kg including battery) |