Description
Features
- Multi-mode capability
- Single-mode testing
- Accurate analysis
- User-friendly operation
Â
Technical Specifications
Wavelengths (nm) | 850/1300, 1310/1550, 1310/1490/1550, 1625 |
Dynamic Range (dB) | 21/19, 32/30, 38/36, 34/36 |
Display | 5.6 in LCD touch screen PON ONTDR |
Loss Threshold (dB) | 0.05 |
Loss Resolution Ratio (dB) | 0.01 |
Distance Scope (km) | 0.18 mi to 111 mi (0.3 km to 180 km) |
Plus, Width (ns) | 5, 20, 40, 80, 160, 320, 640, 1280 or 5, 10, 20, 40, 80, 160, 320, 640, 1280, 2560, 5120, 10240/20480 |
Event Blind Zone (m)³ | 32.8 ft (10 m) |
Attenuation Blind Zone (m)³ | 65.6 ft (20 m) |
Linearity (dB/dB) | ±0.05 |
Sampling Resolution Ratio (m) | 0.4 ft to 26 ft (0.125 m to 8 m) |
Sampling Point | 32 K |
Distance Uncertainty (m) | ± (3.28 ft + 5 x 10^-5 x distance + sampling interval) |
Typical Real-Time Refreshing Duration (s) | 0.2 |
Duration of Measurement | Defined by user, 5s, 10s, 15s, 30s, 1min, 2min, 3min are selectable |
PON OTDR Weight | 3.3 lb. (1.5 KG) |
Dimension (H W D) | 5.9 in x 9.3 in x 2.6 in (15 cm x 23.5 cm x 6.6 cm) |