Description
Features
- User friendly dialog interactive helps operations like Calibration, making curves, etc.
- All tools you need: DAC, AVG, TCG, AWS.
- Pulse Repeatition Frequency: 20-2000Hz precise adjust, high speed scan, no miss out.
- High Signal to noise ratio, clear and stable echo, anti-noise design, perfect for tough working conditions
- 12-digit AD, high speed sampling leads to better echo diagram with all details. Sensitive and can detect even tiny flaws
- Can use probe frequency 20M perfectly
- High speed real-time flaw detection video recording. Unlimited USB data storage.
- IP65 standard. Alloy + Silica gel case, water and dust proof, solid and lasts forever. Damping support makes it stands in any angle
- Battery lasts 15 hours for one charge. Each battery has own charging control so with two batteries it can work around the clock
Technical Specifications
Operating Temperature | 14°F to 122°F (-10℃ to 50℃) |
Storage Temperature | -22°F to 122°F (-30℃ to 50℃) |
Display Delay |  -20 µs to 3400 µs |
Probe Delay/Zero Offset | 0 µs to 99.99 µs |
Rectification | Positive half wave, negative half wave, full wave, RF System |
Gate Monitors | Two independent gates controllable over entire sweep range |
Range | 0 to 393.7in/s (0 to 10000mm), at steel velocity |
Material Velocity | 3.93in to 787.4in (100~20000m/s) |
Pulse Repetition Frequency | 20-2000Hz |
Dynamic Range | ≥38dB |
Linearity | Horizontal: +/-0.2%, Vertical: 2.0%, Amplifier Accuracy +/-1 dB. |
Resolving Power | >40dB (5P14) |
Sensitivity Leavings | >66dB |
Reject (Suppression) | 0 to 80% full screen height |
Probe Types | Single Straight, Single Angle, Daul Straight, Daul Anlge, Thrugh, Creeping, Surface |
Bandwidth (Amplifier bandpass) | 0.2 to 20 MHz |
Power Requirements | AC Mains 100-240 VAC, 50-60 Hz |
Operating Time | 15 Hours |
Recharge Time | 4 Hours |
Pulse Energy | 70V, 100V, 200V, 300V, 400V, 500V selectable |
Dimensions | (240 mm×150 mm × 50 mm) |
Weight | (1.4 kg) |