Description
Overview
GAOTek Automated Display Ultrasonic Flaw Detector is User friendly dialog interactive helps operations like Calibration, making curves, etc. All tools you need: DAC, AVG, colour Boscan, AWS, etc. Pulse Repetition Frequency: 20-3000 Hz precise adjust, high speed scan, no miss out. High Signal to noise ratio, clear and stable echo, anti-noise design, perfect for tough working conditions.12-digit AD, high speed sampling leads to better echo diagram with all details. Sensitive and can detect even tiny flaws. High speed real-time flaw detection video recording. Unlimited USB data storage. Blue tooth connection to mobile device to generate and print detection reports on-site. Alloy + Silica gel case, water and dust proof, solid and lasts forever. Damping support makes it stands in any angle. Battery lasts 15 hours for one charge. Each battery has own charging control so with two batteries it can work around the clock.
Technical Specifications
Range | 0 in to 590.55 in (0 mm to 15000 mm), at steel velocity |
Material Velocity | 100 m/s to 20000Â m/s |
Pulse Repetition Frequency | 20 Hz to 3000 Hz |
Dynamic Range | ≥38 dB |
Linearity: Horizontal | ±0.2% FSW, Vertical: 0.25% FSH, Amplifier Accuracy ±1 db. |
Resolving Power | >40 dBÂ (5P14) |
Sensitivity Leavings | >66 dB |
Reject (suppression) | 0% to 80% full screen height |
Test Modes | Pulse echo, dual element and thru-transmission |
Probe Types | Single Straight, Single Angle, Daul Straight, Dual Angle, Through, Creeping, Surface |
Gate Monitors | Two independent gates controllable over entire sweep range |
Power Requirements | AC Mains 100 V to 240 V AC, 50 Hz to 60 Hz |
Display Delay | -20 µs to 3400 µs |
l Probe Delay/Zero Offset | 0 µs to 99.99 µs |
Storage Temperature | -22 °F to 122 °F (-30 ℃ to 50 ℃) |
Pulse Energy | 200 V, 300 V, 400 V, 500 V selectable |
Rectification | Positive half wave, negative half wave, full wave, RF System |
Bandwidth | 0.2 MHz to 35 MHz |
Gate Monitors | Two independent gates controllable over entire sweep range |
Sensitivity | 120 dB max in selectable resolution 0.1 dB, 1.0 dB, 2.0 dB, 6.0 dB. |
Transducer Connections | BNC or LEMO |
Operating Temperature | 14 °F to 122 °F (-10 ℃ to 50 ℃) |
 H×W×D(mm) | 10.24 in × 6.89 in × 2.36 in (260 mm × 175 mm × 60 mm) |
 Weight | 2.65 lb. (1.2 kg) |