Description
Overview
GAOTek Coating Thickness Gauge with User Cal Base (Unit Change) is designed to measure magnetic and non-magnetic materials with an accuracy of ± [(1% ~ 3%). It uses magnetic thickness measurement method to measure the thickness of the magnetic coating on non-magnetic base. This portable device is ideal for paint shops and electroplaters, for office and specialist advisers, for light and heavy engineering, for the aircraft, shipbuilding, automobile and chemical industries.
Key Features
- Large measurement range: 0 µm-1250 µm.
- Durable material: Wearable ruby probe
- High accuracy: ± [(1%~3%) H+1 µm]
- Easy to use
- Rugged, versatile, one-hand operation
- Auto shut down after 60 seconds of no activity
Technical Specifications
Measuring Range | 0 µm -1250 µm |
Accuracy | ± [(1% ~ 3%) H +1 µm]
H is thickness |
Auto Shut Off | After 60 seconds (if no activity) |
Work Principle | Magnetic |
Dimensions | 4.41 in x 2.72 in x 1.10 in (112 mm x 69 mm x 28 mm) |
Weight | 0.18 lbs. (82 g) |
Working Temperature | 14 °F ~ 140 °F (-10 °C ~ 60 °C) |
Additional Information
Operation Guide
- Power-on and Warm-up
Keystroke once and wait until “READY!” is displayed on the LCD. Now the gauge is ready for measurements.
- Zeroing
Keystroke twice; when “BASE ZERO” is displayed, place flat on surface; hold steady.
After the measurement is obtained, “DONE” is shown and gauge beeps. Then lift the gauge.
- Two-Point User Calibration
Keystroke three times; gauge enters into the mode of two-point user calibration.
When “USER CAL BASE” is shown on the LCD, please conduct a measurement on the base. When “S1” is shown on the LCD, place Shim S1 on the base and conduct a measurement on Shim S1. When “S2” is shown on the LCD, place Shim S2 on the base and conduct a measurement on Shim S2. When “DONE” is displayed, it is ready for use.
- Unit Change
Keystroke four times; convert from µms to mils or vice versa.
- Reset
Keystroke five times; gauge resets.
The device powers down after 60 seconds of no activity.