Description
Features
- 1-6 points calibration with Standard Recognition
- Selectable pH buffer groups, including DIN, NIST, USA, MERK, JIS, GB
- Support for pH standard group customization
- Automatic electrode diagnosis with pH slope and offset display
- 1-5 points calibration with Standard Recognition.
- Adjustable parameters: cell constant, temp, compensation, TDS factor
- Temperature compensation type (none, linear, pure water)
Technical Specifications
pH | |
Range | -2.000 pH to 20.000 pH |
Resolution | 0.1 pH, 0.01 pH, 0.001 pH |
Accuracy | ±0.002 pH |
Calibration Points | Up to 6 |
Standard Customization | Yes |
Calibration Reminder | Yes |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers |
Slope Limit | Yes |
mV/ORP | |
Range | -2000.00 mV to 2000.00 mV |
Resolution | 0.1 mV, 0.01 mV |
Accuracy | ±0.1 mV or ±0.03% of Reading whichever is greater |
EH ORP Mode | Yes |
ORP Calibration Points | 1 custom point (relative mV) |
pX | |
Range | -2.000 pX to 20.000 pX |
Resolution | 0.1 pX, 0.01 pX, 0.001 pX |
Accuracy | ±0.002 pX |
Calibration Points | Up to 6 |
ISE | |
Range | 1.000 e-9 to 9.999 e+9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb |
Resolution | Up to 4 significant digits |
Accuracy | ±0.3% |
Calibration Points | Up to 6 |
Conductivity | |
Range | 0.000 μS/cm to 2000 mS/cm |
Resolution | 0.001 μS/cm minimum, Various with range selection |
Accuracy | ±0.5% FS |
Reference Temperature | 41 °F, 50 °F, 59 °F, 64.4 °F, 68 °F, and 77 °F (5 °C, 10 °C, 15 °C, 18 °C, 20 °C, 25 °C) |
Calibration Points | Up to 5 |
Calibration Reminder | Yes |
Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm |
Resistivity | |
Range | 5 Ωcm to 100 MΩcm |
Resolution | 0.01 Ω·cm minimum |
Accuracy | ±0.5% FS |
TDS | |
Range | 0 ppt to 1000 ppt |
Resolution | 0.001 ppm minimum, changed with range |
Accuracy | ±0.5% FS |
Salinity | |
Type | NaCl |
Range | 0.0 ppt to 80.0 ppt |
Resolution | 0.1 ppt |
Accuracy | ±1 ppt |
Dissolved Oxygen Concentration – Polar graphic | |
Range | 0.00 ppm to 99.99 ppm |
Resolution | 0.01 ppm |
Accuracy | ±0.10 ppm, 0 ppm to 50 ppm ±0.50 ppm, 50 ppm to 99.99 ppm |
Calibration Reminder | Yes |
Calibration Points | Air-saturated water or zero point |
Barometric Compensation | Yes |
Manual Salinity Factor Correction | Yes |
% Saturation – Polar graphic | |
Range | (0.0 to 600) % |
Resolution | 0.10% |
Accuracy | ±2.0% |
Temperature | |
Unit | °C, °F |
Resolution | 0.1 |
Accuracy | ±0.18 °F (±0.1 °C) |
Measurement | |
Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked |
Temp. Compensation | ATC, MTC |
Data Management | |
Data Storage | 1000 Groups |
GLP Features | Yes |
Log Management | Yes |
Inputs | |
pH Electrode | BNC (Q9) |
DO With Temp. Probe | 4-pin aviation connector |
Conductivity With Temp. Probe | 5-pin aviation connector |
Outputs | |
USB | USB 2.0 flash memory device, PC, scanner, |
RS 232 | printer, auto-sampler |
Display Options | |
Backlight | Yes |
Auto Shutdown | 1 min to 60 min, off |
IP Rating | IP 54 |
Date And Time | Yes |
General | |
Power | AC Adapter, 100 V to 240 V AC input, DC 24 V output |
Range | 14 °F to 275 °F (-10 °C to 135 °C) |
Dimensions | 8.66 in × 7.68 in × 2.68 in (220 mm × 195 mm × 68 mm) |
Weight | 2.09 lb. (950 g) |