Description
Overview
GAOTek optic fiber fusion splicer splicing machine is a safety class 3 instrument. The protective features of this product may be impaired if it is used in a manner not specified in the operation instrument. Verify that the product is set to match the available line voltage, the correct fuse is installed, and all safety precautions are taken. Note the instrument’s external markings described under Symbols. The operating display can be changed.
Features
- Handheld Small Light
- 5800 mAh and pluggable Li-battery, Typical 200 cycles
- ARC calibrated by temperature and air pressure automatically
- 8 s splicing time 26 s tube heating time
- USB port for software updating and data record exporting
Technical Specifications
Fiber Count | Single |
Cladding Length | Cladding diameter: 80 µm to 150 µm, Coating diameter: 160 µm to 900 µm |
Typical Splice Loss | SM: 0.02dB;MM: 0.01dB;DS: 0.04dB;NZDS: 0.04dB;G.657: 0.02 dB (ITU-T Standard) |
Return Loss | >60 dB |
Applicable Fibers | SM (ITU-T G.652 & G.657) or MM (ITU-T G.652 & G.657) DS (ITU-T G.652 & G.657) or NZDS (ITU-T G.652 & G.657) |
Fiber Cleaved Length | 0.39 in x 0.62 in (10 mm x 16 mmm) (coating diameter <250 µm); 0.62 in (16 mm) (coating diameter:250 µm to 1000 µm) |
Splicing Program | 40 groups |
Operate Mode | Manual Automatic |
Auto-heating | Available |
Typical Splicing Time | 8 s |
Tube Heating Time | 26 s for 22.3 in x 1.5 in (60 mm x 40 mm) shrinkable sleeves |
Fiber View Magnification | 250X (X or Y view), 125X (X and Y view) |
Viewing Method & Display | 2 CMOS cameras, 4.3 in (10.9 cm) color LCD monitor |
Storage Of Splice Result | 4000 results |
Loss Evaluation | Available |
Tension Test | 1.8 NN to 2.2 N |
Interface | GUI menu interface easier operation |
Battery Capacity | 5200 mAh battery capacity typical times splice and tube heat) |
Power Supply | Adaptor input: AC 100 V to 240 V (50 Hz to 60 Hz) |
Electrode Life | More than 4000 ARC discharge can be replaced conveniently |
Terminals | USB 2.0 port, for uploading splice results and upgrading software |
Power Supply | Adaptor input: AC 100 V to 240 V (50 Hz or 60 Hz) |
Size | 5.8 in x 4.7 in x 5 in (149 mm x 120 mm x 127 mm) |
Weight | With battery 4.1 lb (1.9 kg) |