GAOTek portable DC ground fault detector is developed and manufactured by using phase advance processing technology and data transfer algorithm technology. This product is between the two types of on-line and portable, the use method is portable, and the performance is on-line. The instrument has the characteristics of high detection sensitivity, strong anti-interference ability, small volume, light weight and easy to use. When finding the grounding fault of DC system, it is not necessary to disconnect the power supply, and the grounding point can be located.Â
Features
- Analyzer powered by bus, no external supply needed
- Detect various grounding faults accurately
- Eliminate DC system grounding fault
- Voice interpretation for quick fault location
- Detect size and phase of line leakage current
- Fault current spectrum analysis function
- System to ground voltage measurement
- Low signal output power with current limiting
- Ripple analysis and digital oscilloscope
- Intelligent current clamp with auto-detection
- Detect and locate ring network faults
- Detect mutual faults in DC systems
- Detect battery grounding fault & bus capacitance
- Insulation fault location without power cut off
- Waveform curve & direction display
Technical Specifications
Analyzer | |
Working voltage | take power directly from the bus (working voltage is 48 V to 280 V) |
Voltage measurement range | 0 to 300 V |
Voltage measurement accuracy | 0.5 % |
Bridge working mode | unbalanced bridge |
The measurement range of positive to ground insulation impedance of the system | 0 to 999.9 kΩ |
AC power channeling voltage measurement range | 0 to 280 V |
Overall dimension (L × w × h) | 7.8 in x 5.7 in x 1.8 in (200 mm x 145 mm x 46 mm) |
Power consumption | less than 10 W |
Suitable temperature | 14 F to 122 F (-10 ℃ to +50 ℃) |
Locator | |
Working voltage | 12 V (working voltage of lithium battery is 9.6 V to 12.6 V) |
Detection range of branch grounding resistance | 0 to 300 kΩ |
Branch grounding resistance measurement accuracy | 0 to 100 kΩ ≤ 10 % ± 2 kΩ 100 to 300 kΩ display specific value |
Leakage current detection sensitivity | less than 0.1 mA |
Measurement accuracy | 100 % |
Alarm mode | voice, graphics, data, grounding direction |
Power consumption | less than 1 W |
Overall dimension (L × w × h) | 7.08 in  3.93 in  1.57 in (180 mm x 100 mm x 40 mm) |
Weight | 3.3 lb (1.5 kg) |
Suitable temperature | 14 F to 122 F (-10 ℃ to +50 ℃) |