Description
Introduction
GAOTek Precise Piezoelectric LCR Meter is a new generation impedance tester adopting the most advanced auto balance bridge theory in the world at present. With its 0.05% basic accuracy, speed up to 5.6ms, 20Hz-2MHz frequency range and impedance test range up to 1GΩ, this impedance tester can meet all test demands of components and materials, especially for testing capacitor with low D and inductor with high Q. Four-terminal pair configuration can eliminate the effect of electromagnetic coupling in test cable, to extend the low limit of low impedance test 10 times than those testers with Five-pair configuration.
It supports 20V AC test signal and 40V DC Bias, new-added improved multi parameter list sweep/graphic analyze will help customers to extend the comprehensive evaluation ability on components. It is a strong tool for the design, examination, quality control and production test of electronic components. Its excellent performances and functions provide a powerful tool for circuit design and development, as well as material (electronic material and non-electronic material) research and development. It can realize various tests of commercial standards and military standards, such as IEC and MIL.
Features
- High accuracy: Adopt Auto-balance bridge technology, 4-terminal pair
- High stability and consistency: Up to 15 ranges
- High speed: Up to 5.6ms
- High resolution:7- inch, 800×600
- High power:
- Signal source: Voltage up to 20Vrms (only GAOTek-LCR-260-B) and Current up to 100mA (only              GAOTek-LCR-260-A)
- DC bias: Voltage up to±40V (only GAOTek-LCR-260-B) and Current up to 100mA (only GAOTek-             LCR-260-B)
- 201 Points List Sweep Function
- Multi-parameter Graphic Sweep Function
- Arithmetical operation
- 10 bins sorting, sorting result with sound and light alarm
- Huge storage space: Internal: 100 groups of setting files, 10 groups of gif image files External: 100 groups of setting files through USB storage
- Rich interfaces: USB HOST, USB DEVICE, LAN, HANDER, GPIB (Optional), SCANER(Optional), external DC BIAS control interface
Technical Specifications
Model | GAOTek-LCR-260-A | GAOTek-LCR-260-B | GAOTek-LCR-260-C | |
Test Signal Source | ||||
Output impedance | 100Ω, ±1% @1kHz | |||
Frequency | Range | 20Hz-2MHz | 20Hz-1MHz | |
Resolution | 20.0000Hz – 99.9999Hz 0.1mHz | |||
100.000Hz – 999.999Hz 1mHz | ||||
1.00000kHz – 9.99999kHz            10mHz | ||||
10.0000kHz – 99.9999kHz            0.1Hz | ||||
100.000kHz – 999.999kHz            1Hz | ||||
1.00000MHz – 2.00000MHz 10Hz | ||||
AC test signal | Rated value (ALC OFF):
Set the voltage as the Hcur voltage when the test terminal is open Set the current as the Hcur current when the test terminal is short Constant value (ALC ON): Keep the voltage in DUT is the same as the set value Keep the current in DUT is the same as the set value |
|||
AC signal |
Voltage range | 5mVrms – 2Vrms | F≤1MHz 5mVrms- 20Vrms F >1MHz 5mVrms – 15Vrms | 5mVrms – 2Vrms |
Resolution | 5mVrms – 0.2Vrms          100μVrms | |||
0.2Vrms – 0.5Vrms          200μVrms | ||||
0.5Vrms – 1Vrms              500μVrms | ||||
1Vrms – 2Vrms  1mVrms | ||||
2Vrms – 5Vrms  2mVrms | ||||
5Vrms – 10Vrms 5mVrms | ||||
10Vrms – 20Vrms            10mVrms | ||||
Current range | 50μArms – 20mArms | 50μArms -100mArms | 50μArms – 20mArms | |
Resolution | 50μArms – 2mArms        1 μArms | |||
2mArms – 5mArms         2 μArms | ||||
5mArms – 10mArms       5 μArms | ||||
10mArms – 20mArms    10μArms | ||||
20mArms – 50mArms    20μArms | ||||
50mArms-100mArms    50μArms | ||||
Rdc test | Voltage range | 100mV — 2V | ||
Resolution | 100μV | |||
Current range | 0mA— 20mA | |||
Resolution | 1μA | |||
DC Bias | Voltage range | 0V — ± 10V | 0V — ± 40V | 0V — ± 10V |
Resolution | 0V – 5V 100μV | |||
5V – 10VÂ Â Â Â Â Â Â Â Â Â Â Â Â Â 1mV | ||||
10V – 20VÂ Â Â Â Â Â Â Â Â Â Â 2mV | ||||
20V – 40VÂ Â Â Â Â Â Â Â Â Â Â 5mV | ||||
Current range | 0mA— ± 100mA | |||
Resolution | 0 A – 50mA         1μA | |||
50mA – 100mA 10μA |