Features
- Automated switch three staff gauge (Depth d, level p, distance s)
- Automated display precise flaw location
- Automated transducer calibration
- Convenient DAC or TCG and AVG creation
- 6 dB DAC functions
- Crack Height Measure function
- 500 setups, input criteria freely, work without a test block
- Big memory of 1000 A graph
- Automated gain and gain scan
- Peak Hold and Peak Memory
- B scan
- AWS D1.1
- Alarm: Beep and LED.
- Real Time Clock.
- Fill echo.
- Capture mark.
- Echo color within the Gate.
- Automated video recording, playback
- Powerful pc software and reports can be exported to excel
- Li battery, continue working time up to 10 hours
- The embedded software can be online updated
Technical Specifications
Measuring Range (mm) | 0 in to 393.7 in (0 mm to 10000 mm) |
Vertical Linearity Error | ≤3% |
Horizontal Linearity Error | ≤0.1% |
Sensitivity Leavings | ≥62 dB |
Dynamic Range | ≥32 dB |
Resolving Power | ≥36 dB |
Frequency Range | 0.5 MHz to 15 MHz |
Gain | 0 dB to 120 dB |
Material Velocity | 1000 m/s to 15000 m/s |
Measurement Mode | Single, Dual, Thru |
Reject | 0% to 80% |
Pulse Displacement | -20 μs to 3400 μs |
Zero | 0.0 μs to 99.99 μs |
Port Type | BNC (Q9) |
Operating Temperature | 28 °F to 122 °F (-20 ℃ to 50 ℃) |
Dimension | 9.44 in x 6.14 in x 1.89 in (240 mm × 156 mm × 48 mm) |
Weight | 2.2 lbs (1.0 kg) (with battery) |