Description
Overview
GAOTek Megohmmeter with Data Storage (Auto Voltage Release) measures insulation resistance and displays automatic release of voltage and comes with 18 groups of data storage capacity. This device has computer technology as kernel and LSI combined with digital circuit to measure insulation resistance. It is equipped with strong measurement and data processing software, displays automatic release of voltage, has stable features and is easy to operate. The instrument will Auto power off if there is no operation in 15 minutes after completion of the test. Polarization Index test can be conducted between any two time in order to auto-test the resistance ratio according to the setting.
Key Features
- Automatic release of the voltage
- Back light function making it convenient to working in dark environments.
- Test results displayed in bar pattern
- HV indicating symbol and red warning light
- Auto power off if no operation in 15 min after completion of test.
- Stores 18 groups of data.
- Time setting: to test within 15 minutes of the setting time
- COMP measurement (comparing function)
- Polarization index test
Technical Specifications:
Voltage Test
DC voltage | AC voltage | |
Measurement range | ±30 V ~ ±600 V | 30 V ~ 600 V (50 Hz/ 60 Hz) |
Resolution | 1 V | |
Accuracy | ±(2 % + 5) | < 100 V: ± (2 % + 8) |
≥ 100 V: ± (2 % + 5) | ||
Display | LCD, the maximum reading is 9999 | |
Low battery warning | Three cell | |
Overrun indication | “OL” symbol appear on the insulation resistance range. | |
Range Function | Automatic | |
Unit display | With functions, quantity of electricity display in symbol | |
Current consumption | 600 mA (maximum) (usually keep it to be 20 mA) | |
Service conditions | Temperature: 32 °F – 104 °F (0 °C ~ 40 °C)
Humidity: < 85 % RH |
|
Storage Conditions | Temperature: -4 °F to 140 °F (-20 °C ~ 60 °C)
Humidity: < 90 % RH |
|
Dimension | 7.95 in × 6.10 in × 3.700 in (202 mm x 155 mm x 94 mm) | |
Weight | 4.40 lbs (2 kg) (includes the battery ) |
Insulation Resistance Test
Rated Voltage | 500 V | 1000 V | 2500 V | 1500 V |
Measurement range | 0.5 MΩ ~ 5.0 GΩ | 2 MΩ ~ 10.0 GΩ | 10 MΩ ~ 100 GΩ | 5 MΩ ~ 20.0 GΩ |
Open-circuit voltage | DC 500 V + 20 %, -0 % | DC 1000 V + 20 %, -0 % | DC 2500 V + 20 %, -0 % | DC 1500 V + 20 %, -0 % |
Rated measurement current | load: 500 KΩ
1 mA ~ 1.2 mA |
load: 1 MΩ
1 mA ~ 1.2 mA |
load: 2.5 MΩ
1 mA ~ 1.2 mA |
load: 1.5 MΩ
1 mA ~ 1.2 mA |
Accuracy | 100 KΩ ~ 100 MΩ; ± (3 % + 5), 100 MΩ ~ 10 GΩ ± (5 %+5), 10 GΩ ~ 100 GΩ; ± (10 % + 5) |
Standard Accessories
- Test wire
- Battery (alkaline or carbonic) 1.5 V (LR 14) x8 or DC 15 V power adapters
- Interface Software CD
- USB
- Instruction manual
- Carrying Case
Optional Accessories
Special power adaptor (input voltage: 230 V, 50 Hz/ 60 Hz, 50 mA, output: DC 14.5 V, 600 mA)