Description
Overview
GAOTek Optical Loss Test results starts with proper test cord referencing. Accurate referencing greatly reduces common mistakes often encountered in the field. Thanks to the reference assistant’s animated and interactive interface this step of the testing sequence is now as simple and easy as it can be.
Features
- Unmatched FasTesTâ„¢ performances: 100 %
- automated bidirectional
- test at two wavelengths under 5 sec
- 100 % automated fiber inspection
- one-step process with pass
- fail analysis at both fiber ends.
- On-board assistant and diagnosis
- eliminate reference errors and negative loss.
- Improved short fiber measurement.
- On board professional PDF reporting.
- Bright, 7 in (17.7 cm) high resolution
- touchscreen display
- the biggest in the market
- Best-in-class single mode
- distance range of 124.2 mi (200 km)
- EXFO Connect-ready for cloud-based test assets management.
- Wi Fi connectivity (optional)
Â
Technical Specifications
Measurement range | 25 dBm to 50dBm |
Uncertainty | ± (5 % + 10 nW) |
Wavelengths range | 850, 1300, 1310, 1490, 1550, 1577, 1625, 1650nm |
Tone detection (Hz) | 270 or 330 or 1000 or 2000 |
Testing speed | FasTesTâ„¢ Simplex:Â 2.6 sec
(two wavelengths, one direction, automated, IL+fiber length) (two wavelengths, bidirectional, automated, IL + ORL + fiber length) |
Input or Output connectors | Interchangeable adapter (LC, SC or FC) |
Wavelengths |   Quad              MM                SM 850 ± 20          850 ± 20          1310 ± 20 1300 ± 20         1300 ± 20          1550 ± 20 1310 ± 20 1550 ± 20 |
Source type | LED (multimode) LED Laser, Laser (single mode) |
Launch condition | EF compliancy guaranteed at multimode source port Within TIA to 526 to 14 to B, ISO or IEC 14763 to 3 and IEC 61280 to 4 to 1 Encircled Flux template limits at the end of an EXFO reference grade 50 or 125 µm test cord |
Length measurement range (km) | Multimode (MM): 12.43 mi (20 km) Single mode (SM): 99.42 mi (160 km) |
Length measurement uncertainty | ± (1.64 ft (0.5 m) + 0.5 % x length) |
ORL measurement range (dB) | 50 dB |
ORL measurement uncertainty (dB) | ±1 dB |
Output power (dBm) | Multimode: –25 dBm Single mode: 2.5 dBm |
Output power stability (dB) | ±0.05 over 8 hrs |
Spectral width (FWHM) (nm) | 850 nm: 30 to 60 1300 nm: 100 to 150 |
Temperature Operating | 14 °F to 122 °F (–10 °C to 50 °C) |
Temperature Storage | –22 °F to 158 °F (–30 °C to 70 °C) |
Relative humidity | 0 % to 95 % noncondensing |
Interfaces | Two USB 2.0 ports RJ45 LAN 10 or 100 Mbit or s |
Storage | 6 GB internal memory (150 000 test results, typical) |
Battery | Rechargeable lithium-polymer battery 12 hrs of operation |
Power supply | AC or DC adapter, input 100 V to240 VAC, 50 to 60 Hz, 9 to 16 V DCIN 20 W min |
Display | 7-in (17.7 cm) outdoor-enhanced touchscreen, 800 x 480 TFT |
Size (H x W x D) | 6.53 in x 7.87 in x 2.67 in (166 mm x 200 mm x 68 mm) |
Weight (with battery) | 3.3 lb. (1.5 kg) |