Below are general answers on how to operate, maintain, and calibrate a turbidimeter from the list of GAO Tek’s turbidimeters. To facilitate our customers to a selection of our products, we have further classified our turbidimeters by their features: color interference, colored sample, colored water, drinking water, formazin standard, handheld, high precision, high range, high-level, industrial, laboratory & research, low turbidity range, moderate range, multi-parameter, nephelometric, ratio, rugged,  field kits, and NTU.

We have products in stock and can ship overnight to most places in the U.S. and Canada.

If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.

 

Operating a Turbidimeter:

Preparation:

  • Ensure the turbidimeter is placed on a stable surface, away from direct sunlight or sources of glare.
  • Check that the instrument is clean and free from any residue or debris that could affect readings.

Sample Collection:

  • Collect a representative sample of the water to be tested in a clean, transparent container.
  • Avoid introducing air bubbles into the sample, as they can interfere with the measurement.

Instrument Setup:

  • Turn on the turbidimeter and allow it to warm up for the specified time, typically a few minutes.
  • Follow the manufacturer’s instructions to select the appropriate measurement range or calibration settings based on the expected turbidity of the sample.

Calibration:

  • If the turbidimeter requires calibration, follow the calibration procedure outlined in the manufacturer’s instructions. Calibration typically involves using standard calibration solutions of known turbidity values.
  • Ensure the calibration is performed regularly according to the recommended frequency to maintain accuracy.

Measurement:

  • Fill the sample cell with the prepared water sample, ensuring there are no air bubbles trapped inside.
  • Place the sample cell into the turbidimeter according to the manufacturer’s instructions.
  • Initiate the measurement and record the turbidity reading displayed on the instrument.

Cleaning and Maintenance:

  • After use, clean the sample cell and any other components that came into contact with the sample to prevent contamination.
  • Store the turbidimeter in a clean and dry environment when not in use.
  • Follow any specific maintenance procedures recommended by the manufacturer to ensure the instrument’s performance and longevity.

 

Maintaining a Turbidimeter:

Regular Cleaning:

  • Clean the optical surfaces of the turbidimeter, including the sample cell and lenses, using a mild detergent or cleaning solution recommended by the manufacturer.
  • Avoid using abrasive materials or harsh chemicals that could scratch or damage the optical surfaces.

Quality Control:

  • Implement a quality control program to monitor the performance of the turbidimeter over time.
  • Periodically test the instrument using certified reference materials or standard calibration solutions to verify its accuracy and precision.

Calibration Verification:

  • Perform calibration verification checks periodically to ensure the turbidimeter remains within acceptable calibration limits.
  • Compare the instrument’s readings with known reference standards to identify any deviations and take corrective action if necessary.

Replacement of Consumables:

  • Replace any consumable components of the turbidimeter, such as cuvettes or light sources, according to the manufacturer’s recommendations.
  • Ensure that replacement parts are compatible with the specific model of turbidimeter to maintain optimal performance.

 

Calibrating a Turbidimeter:

Prepare Calibration Standards:

  • Obtain certified turbidity standard solutions with known turbidity values spanning the measurement range of the turbidimeter.
  • Ensure the calibration standards are stored and handled according to the manufacturer’s recommendations to maintain their integrity.

Perform Calibration:

  • Follow the manufacturer’s instructions to initiate the calibration procedure.
  • Typically, calibration involves inserting the calibration standard into the turbidimeter and adjusting the instrument’s settings to match the known turbidity value of the standard.
  • Repeat the calibration process for multiple standard solutions to cover the full range of turbidity measurements if necessary.

Verification:

  • After calibration, verify the instrument’s performance by measuring additional calibration standards or reference samples.
  • Compare the measured values to the known turbidity values to confirm that the turbidimeter is accurately calibrated.

Documentation:

  • Keep detailed records of the calibration process, including the date, calibration standards used, and any adjustments made to the instrument.
  • Maintain calibration certificates and documentation for reference and audit purposes.