Below are general answers on how to operate, maintain, and calibrate an ammonia gas detector from the list of GAO Tek’s ammonia gas detectors. To facilitate our customers to a selection of our products, we have further classified our ammonia gas detectors by their features: benchtop, data logging, explosion proof, farming, handheld, industrial, outdoor, rugged, and wireless.
We have products in stock and can ship overnight to most places in the U.S. and Canada.
If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form  or email us.
Â
Operating GAO Tek’s Ammonia Gas Detector:
Read the Manual:
- Begin by thoroughly reading the user manual provided by GAO Tek. This will provide specific instructions and guidelines for your particular model.
Power On/Off:
- Follow the GAO Tek’s instructions to power on the ammonia gas detector. Some detectors may have a warm-up time, so allow it to stabilize before use.
- Ensure that the power source (batteries or external power) is sufficient for proper operation.
Sensor Placement:
- Place the ammonia gas detector in an area where ammonia exposure is likely.
- Ensure that the detector is not obstructed by barriers or located in a spot where air circulation is limited.
Adjust Alarm Thresholds:
- Set the alarm thresholds based on the permissible exposure limits (PEL) for ammonia. This information can be obtained from safety regulations or guidelines applicable to your industry.
Monitor Readings:
- Regularly monitor the readings on the display. If the readings approach or exceed the alarm thresholds, take appropriate action, such as evacuating the area or addressing the source of ammonia release.
Â
Maintaining an Ammonia Gas Detector:
Regular Inspections:
- Inspect the detector for any physical damage, corrosion, or loose connections.
- Check the sensor and sampling system for dust or debris that could affect accuracy.
Calibration Check:
- Periodically perform a calibration check to ensure the accuracy of the readings. This can be done using a known concentration of ammonia gas or a calibration gas.
Battery Replacement:
- If the ammonia gas detector is battery-powered, replace the batteries according to GAO Tek’s recommendations.
Software/Firmware Updates:
- Stay informed about any software or firmware updates provided by GAO Tek and apply them as needed.
Â
Calibrating an Ammonia Gas Detector:
Select a Calibration Gas:
- Choose a calibration gas that is certified and has a known concentration of ammonia. This gas should closely match the expected conditions in your working environment.
Ventilate the Area:
- Before calibration, ensure that the calibration area is well-ventilated to avoid exposing personnel to the calibration gas.
Perform the Calibration:
- Follow GAO Tek’s instructions to introduce the calibration gas to the detector. This may involve connecting the calibration gas cylinder to the detector and allowing the system to adjust.
Adjust Settings:
- If the readings do not match the expected concentration of the calibration gas, adjust the calibration settings according to GAO Tek’s instructions until accurate readings are achieved.
Document Calibration:
- Keep a record of each calibration, including the date, time, calibration gas concentration, and any adjustments made during the process.
Calibration Interval:
- Determine the calibration interval based on GAO Tek’s recommendations, regulatory requirements, and the environmental conditions in which the detector operates.
Document Calibration:
- Keep a record of each calibration, including the date, time, calibration gas concentration, and any adjustments made during the process.