Description
Overview
GAOTek Fiber Optic Pre-terminated Cable MM/SM for Indoor/Outdoor are superior full-line fiber optic cables that can be used in large data centers or typical LAN offices or in campus-wide networks to reduce time in deployment and to improve project investments. Pre-terminated assemblies include ribbon fan-out fiber optic assemblies and bundle fan-out fiber optic assemblies. The fiber optic assemblies are available in Type A – Standard Orientation, Type B – physically flipped orientation and Type C – reverse fiber positioning orientation with imported MPO/ MTP connectors to meet high-density fiber installation requirements. They offer a streamlined solution for deployment and fiber management without extra cable to be routed for indoor/ outdoor applications. The assemblies are pre-terminated in factory to save time and cost at the fiber installation site.
Features
- The fiber optic cables are RoHS Compliant and meet Telcordia GR-326-Core Standards.
- Supports industry standard single-mode and multimode connectors.
- The cables support typical IL less than 0.2 dB or less, exceeding the industry standard.
- Supports tensile strength of up to max 31 lbs (14 Kg).
- It is 100% optical performance tested before packed.
- All Multimode Pre-Terminated Assemblies can be customized with Corning fiber specifications.
- The cables come in standard PE plastic bag with test sheet or customized.
- Supports wide variety of cable and connector options.
- Rapidly deployable and ready for installation on arrival.
- Supports improved end-to-end attenuation, throughput and application migration.
Technical Specifications
Fiber Count | 12 | |
Fiber Type | Single Mode and Multi-Mode | |
Cladding Diameter | 125 ± 1 µm | |
Length | 492 ft. (150 m) | |
GEOMETRICAL CHARACTERISTICS | ||
Cladding Diameter | 125 µm ± 1 µm | |
Cladding Non-Circularity | ≤ ±1.0 % | |
Core-Cladding Concentricity Error | ≤ 0.6 µm | |
Coating Diameter | 245 µm ± 5 µm | |
Cladding-Coating Concentricity Error | ≤ 12 µm | |
Coating Non-circularity | ≤ 3.0 % | |
Curl | ≥ 4 m | |
MECHANICAL CHARACTERISTICS | ||
Tensile Proof test |
≥ 1.02 % | |
≥ 9.1 N | ||
≥ 0.704 Gpa | ||
Coating Strip Force | ||
Peak Force | 1.3 N -8.9 N | |
Typical Value | 1.9 N | |
Tensile Strength | ||
Weibull Probability 50% | ≥ 4000 Mpa | |
Weibull Probability 15% | ≥ 3050 Mpa | |
Dynamic Fatigue Parameter |  ≥ 20 Nd | |
1 turn, 0.4 in (10 mm) radius | 1550 nm | ≤ 0.75 dB |
1625 nm | ≤ 1.5 dB | |
10 turns, 0.6 in (15 mm) diameter | 1550 nm | ≤ 0.25 dB |
1625 nm | ≤ 1.0 dB | |
Fiber Length (Length Per Spool) | 1.3 mi – 3.8 mi (2.1 km – 6.1 km) |
Additional Information
Applications
- With low dispersion, attenuation and PMD, AOP matched cladding single-mode optical fiber is applicable to
- Long-haul Trunks Communication,
- CATV and
- Loop Feeder.
- It could be used in all types of optical cables, including
- ribbon optical cables,
- slotted cord cables,
- standard loose tube cables,
- central-tube optical cables,
- ADSS, OPGW and indoor tight-buffer cables.
 Cable Reference
Connector Type | Fiber Item |
LC/ APC | Multimode; 50/125 µm |
LC/ PC | Single mode; 9/125 µm |
SC/ APC | Multimode; OM3-300 |
SC/ PC | Single mode; OS2; OS1 |