Advanced True RMS AC/DC Clamp Meter with VFD & iFlex Tools- GAOTek

Advanced True RMS AC/DC Clamp Meter with VFD, iFlex, precise measurements, robust safety, portability, and versatile features for professionals. 

SKU: GAOTek-CM-133 Category:
Description

Description

Overview

GAOTek AC or DC Clamp Meter measures very low and very high resistance with this True RMS AC or DC clamp meter. It features a VFD low-pass filter, which provides accurate motor drive measurements and is ideal for troubleshooting non-linear signals. Additionally, this instrument is compatible with the Fluke Connect application and iFlex flexible current probe.

 

Features

  • Read measurements on your phone at a safe distance
  • Wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Capture intermittent faults and multitask with Fluke 375 FC’s logging
  • Create and share reports from the field via email
  • Converse in real-time with Share Live™ video calls
  • Compatible with iFlex flexible current probe
  • Use to expand the measurement range to 2500 A ac
  • Provides access to large conductors in tight spaces
  • Compatible with TPAK magnetic hanging strap
  • Integrated VFD low pass filter for accurate motor drive measurements

 

Technical Specification

Range 600 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits (10 to 100 Hz)
2.5 % ± 5 digits (100 to 500 Hz)
Crest Factor (50 or 60 Hz) 3 at 500 A
2.5 at 600 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3 % ±5 digits (5 to 500 Hz)
Crest Factor (50 or 60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. > 2
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5 % ± 5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1 % ± 5 digits
mV DC
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % ± 5 digits
Frequency via Jaw
Range 5.0 to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ± 5 digits
Trigger Level 5 to 10 Hz, ≥ 10 A
10 to 100 Hz, ≥ 5 A
Frequency via Flexible Current Probe
Range 5.0 to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ± 5 digits
Trigger Level 5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1 % ± 5 digits
Capacitance
Range 1000 µF
Resolution 0.1 µF (≤ 100 µF)
1 µF (≤ 1000 µF)
Accuracy 1 % ± 4 digits
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground 1000 V
Batteries 2 x AA alkaline, NEDA 15A, IEC LR6
Operating Temperature 14 °F to 122 °F (-10 °C to 50 °C)
Storage Temperature 40 °F to 140 °F (-40 °C to 60 °C)
Operating Humidity – Non-Condensing (< 50 °F (10 °C)) ≤ 90 % RH at 50 °F to 86 °F (10 °C to 30 °C)
≤ 75 % RH at 86 °F to 104 °F (30 °C to 40 °C)]
Operating Altitude 1.86 mi (3000 m)
Storage Altitude 24.46 mi (12,000 m)
Jaw Opening 0.02 mi (34 mm)
Flexible Current Probe Diameter 24.60 ft (7.5 mm)
Flexible Current Probe Cable Length (Head to Electronics Connector) 5.90 ft (1.8 m)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V or CAT IV 600 V
IP Rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Dimensions 9.8 in x 3.3 in x 1.8 in (249 mm x 85 mm x 45 mm)
Weight 0.87 lb (395 g)