Description
Overview
GAOTek clinical laboratory colorimeter has 10.5 in (26.6 cm) touch PAD which is used as a display interactive interface. According to CIE, the geometric optical structure D per 8 ° (reflection) and D per 0 ° (transmitted), the instrument can measure reflection or transmission and colorimetric data of various samples. The instrument with 1 in (25.4 mm), 0.5 in (15 mm), 0.3 in (8 mm), 0.1 in (4 mm) various reflective aperture to meet various test occasions. This instrument with accuracy and stability measurement, large storage capacity, equipped with USB and bluetooth dual communication modes, and PC-site color management software achieve more extension functions, which can be used for precision analysis and transmission of color.
Technical Specifications
Optical Geometry | Reflect D per 8 (diffused illumination, 8 ° viewing angle), SCI (specular component included) or SCE (specular component excluded), include UV or excluded UV light source. Transmittance D per 0 (diffuse illumination 0° viewing), SCI (specular component included) or SCE (specular component excluded), include UV or excluded UV light source, HAZE (ASTM D1003). Standards meet CIE No.15, GB per T 3978, GB 2893, GB per T 18833, ASTM E1164, DIN5033 Teil7, JIS Z8722 under condition C |
Integrating Sphere Size | 6.06 in (154 mm) |
Light Source Device | 360 nm to 780 nm wavelength range, combined LED Light. Including UV, 400nm cut-off light source, 420nm Cut-off light source, 460nm cut-off light source |
Spectrophotometric Mode | Concave grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360 nm to 780 nm |
Wavelength Interval | 10 nm |
Semiband Width | 5 nm |
Reflectance Range | 0% to 200% |
Reflectivity Resolution | 0.01% |
Measuring Aperture | Reflective XLAV 1 in (25.4 mm) or 1.1 in (30 mm), LAV 0.5 in (15 mm) or 0.7 in (18 mm), MAV 0.3 in (8 mm) or 0.39 in (10 mm), SAV 0.15 in (4 mm) or 0.2 in (6 mm). Transmissive 1 in (25.4 mm) (no limit on sample height and width, but thickness ≤2.1 in (≤54 mm) |
Specular Component | Reflectance SCI and SCE or transmittance SCI and SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
Color Difference Formula | E x ab, E x uv, E x 94, E x cmc, E x cmc, E x 00, E (Hunter), E x CH, 555 Index |
Another Colorimetric Index | WI (ASTM E313, CIE or ISO, AATCC, Hunter), YI (ASTM D1925,ASTM 313), MI (Metamerism Index), staining fastness, color fastness, color strength, opacity, APHA or Hazen or Pt-Co Index, Gardner Index Haze, Transmission (ASTM D1003), Saybolt index, ASTM D1500 Color code, 8° Gloss, 555 Index, carbon (My,dM), color density CMYK (A,T,E,M), tint, color density (part function achieved via software in PC) |
Observer Angle | 2 ° or 10 ° |
Illuminant | D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30, B, U35, NBF |
Displayed Data | Spectrogram or values, chromaticity values, color difference values or graph, pass or fail result, color offset, color assessment, haze, liquid chromaticity |
Measuring Time | 2.0 seconds (measure SCI and SCE meantime about 4 seconds) |
Repeatability | Reflectance chromaticity value 1 in (25.4 mm) or SCI, Standard deviation within E x ab 0.015 (when a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | 1 in (25.4 mm) or SCI, within E x ab 0.15 |
Power | AC 24 V, 3 A Power adapter power supply |
Illuminant life Span | 5 years, more than 3 million times measurements |
Display | 10.5 in (26.6 cm) rotatable display pad |
Data Port | USB and Bluetooth 5.0 |
Data Storage | 128 G storage, above 100000 pieces |
Operating Environment | 32 °F to 104 °F (0 °C to 40 ℃) |
Storage Environment | -4 °F to 122 °F (-20 °C to 50 ℃) |
Dimension | 17.3 in x 9.7 in x 11.1 in (440 mm x 248 mm x 283 mm) |
Weight | Approximately 29.7 lb (13.5 kg) |