Description
Overview
GAOTek solar radiation and pyranometer is an instrument applied in the field of photovoltaic power stations and new energy monitoring. The product indicatively integrates all meteorological parameters that need to be monitored in the operation and maintenance management of photovoltaic power stations into one structure, which can be measured at the same time: ambient temperature, relative humidity, component temperature, wind speed, wind direction, atmospheric pressure, total solar radiation poa and total daily cumulative radiation amount.
Features
- Small in size
- High integration
- Easy to install
- Protective cover with special process heat insulation treatment
- Support extended parameter measurement
- Free testing software
Specifications
Relative Humidity | Measuring Range : 0% to 100% RH
Accuracy : ±3% RH (<80% RH, No Condensation) Resolution: 0.01% RH Sampling frequency: 1 HZ |
Component Temperature | Measuring Range : -4 ℉ to 176 ℉ (-20℃ to +80℃)
Accuracy: ≤ ± 32.36 ℉ (0.2 ℃) Resolution: 32.18 ℉ (0.1 ℃) Sampling frequency: 1 HZ |
Wind Speed | Measuring range: 0 m/s to 60 m/s
Accuracy: ±(0.3 V + 0.03 V)M/S;V ≤30 M/S ±(0.3 V + 0.05 V)M/S; V ≥30 M/S (V stands for standard wind speed in a wind tunnel) Resolution: 0.01 m/s ampling frequency: 4 HZ |
Wind Direction | Measuring range: 0° to 359.9°
Accuracy: ±3° (when Wind Speed =10 m/s) Resolution: 0.1° Sampling frequency: 4 HZ |
Atmospheric Pressure | Measuring range: 500 hPa to 1100 hPa
Accuracy: ±0.5 hPa(77 ℉ (25℃),950 hPa to 1100 hPa) Resolution: 0.1 hPa Sampling frequency: 1 HZ |
Total Solar Radiation POA | Measuring range: 0 W/m2 to 2000 W/m2
Accuracy: ≤ ±3% Resolution: 1 W/m2 Sampling frequency: 1 HZ |
Output | Standard product with RS485 interface, ModbusRTU;
Customizable option SDI-12(Extra costs apply) |
Maximum Output Frequency | Passive Mode: 1/S Active Mode: 1/min |
Power Supply | DC 12 V to 24 V |
Solar Radiation Gauge Adjustment Panel | Adjustable Range: 0° to 60°
(General Standard Selection 40°) |
Level of Protection | IP65 |
Mounting Manner | Standard Product is sleeve fixed (Optional: matching parts, extra costs apply, see Accessory and Parts) |
Fixed Trestle | Optional: 1.5 meter, or 1.8 meter bracket (extra cost apply) |
Cable | 3 meter cable line (Optional: 10 meter cable line available for extra cost ) |
Ambient Temperature | Measuring Range : -40 ℉ to 185 ℉ (-40 ℃ to 85 ℃)
Accuracy : ± 32.54 ℉ (0.3℃) @ 77 ℉ (25℃) Resolution: 32.02 ℉ (0.01 ℃) Sampling frequency: 1 HZ |
Component Temperature | Measuring Range : -4 ℉ to 176 ℉ (-20℃ to +80℃)
Accuracy: ≤ ± 32.36 ℉ (0.2 ℃) Resolution: 32.18 ℉ (0.1 ℃) Sampling frequency: 1 HZ |
Operating Temperature | -40 ℉ to 176 ℉ (-40 ℃ to 80 ℃) |