Description

Description

Features

· Professional portable meter to check and record indoor air quality
· Big LCD with blue back light to use in dark area
· One touch to display
· Designed with NDIR (non-dispersive infrared) wave guide technology CO2 sensor
· Designed with fast response electrochemical CO sensor
· Programmable warning CO level
· Long time drift compensation on CO2 sensor
· Audible alarm (< 80 dB) threshold setting
· Max, Min, TWA, SETL, average, hold functions included
· Mini USB output to PC download function for data analysis
· 99 points manually recording could be review
· Up to 32000 points auto logging memory
· Housing design surrounds with rails to help Air ventilation for quick and accurate response
· Easy to manually calibrate CO2 at fresh air around 380 to 420 ppm
· Manual calibration is also available for CO
· RH sensor could be calibrated with AZ 33 % / 75 % salt bottle easily

 

Technical Specifications

CO2 Range 0 ppm to 9999 ppm (5001 ppm to 9999 ppm out of scale range)
CO2 Resolution 1 ppm
CO2 Accuracy ± 30 ppm ± 5 % of reading (0 ppm to 5000 ppm), other range are not specified
CO2 Response Time < 30 Sec (90 % step change)
CO2 Warm-up Time 30 Sec
CO Range 0 ppm to 1000 ppm
CO Resolution 1 ppm
CO Accuracy ± 3 ppm for less than 20 ppm,± 5 ppm for less than 100 ppm,

± 10 % of reading for 101 ppm to 500 ppm,

± 20 % of reading for 501 ppm and above

CO Response Time < 60 Seconds (90 % step change)
Air Temperature Range -5 ℉ to 140 ℉ (- 20 ℃ to 60 ℃)
Air Temperature Resolution 0.1 ℉ (0.1 ℃)
Air Temperature Accuracy ± 0.9 ℉ (± 0.6 ℃)
Air Temperature Response Time < 2 mins (90 % step change)
Relative Humidity Range 0 % RH to 99.9 % RH
Relative Humidity Range 0.1 % RH
Relative Humidity Accuracy ± 3 % RH (at 77 °F (25 ℃), 10 % to 90 % RH); others ± 5 % RH
Relative Humidity Response Time < 10 mins (90% step change)
Dew Point Temp. (DP) -4 °F to 139.62 °F (-20 ℃ to 59.9 ℃)
Wet Bulb Temp. (WB) -23 °F to 139.62 °F (-5 ℃ to 59.9 ℃)
LCD Size 1.73 in x 1.02 in (44 mm x 26 mm)
Meter Size 8.07 in x 2.75 in x 2.20 in (205 mm x 70 mm x 56 mm)
CO2 Sensor Operating Temperature -4 °F to 122 °F (-20 ℃ to 50℃)
CO Sensor Operating Temperature -4 °F to 140 °F (-20 ℃ to 60 ℃)
Other parameters Operating Temperature -4 °F to 140 °F (-20 ℃ to 60 ℃)
Storage Temperature -4 °F to 140 °F (-20 ℃ to 60 ℃)
Storage RH% 10 % RH to 90 % RH (avoid condensation)
Power Supply AA x 4 PCS or 9 V adaptor
Battery life > 24 hours (Alkaline Battery)
IP Rating > IP 40
Weight 0.441 lb. (200 g)