Description
Overview
GAOTek Multiparameter Water Quality Monitoring presents a comprehensive and advanced solution for real-time water quality assessment. Offering a wide range of precise and simultaneous measurements, this multiparameter sondes system is designed to efficiently gather critical data regarding various water quality parameters. Its user-friendly online capabilities enable continuous remote monitoring and data collection, facilitating prompt decision-making for environmental management and protection. The durable construction ensures reliability even in challenging aquatic environments. However, it demonstrates significant potential, further information regarding its calibration accuracy, long-term stability, and compatibility with different water bodies would provide a more comprehensive understanding of its overall performance and suitability for specific monitoring applications.
Features
- Optional self-cleaning system to get accurate data for a long time.
- Real-time data collection, calibration, and network connectivity options
- Extension cables support internal/external stretch, with 44.09 lb capacity
- Simple and quick to replace the electrode at sight
- Power Save, can flexibly set the sampling interval time, optimize the work / sleep time
- Sensor power supply positive and negative reverse connection protection
- Sensor RS485 A/B terminal is connected to the power supply protection
Technical Specification
Depth | Principle: Pressure-sensitive Method |
Range: 0 in to 2401.57 in (0 mm to 61000 mm) | |
Resolution: 0.78 in (200 mm) | |
Accuracy: ±0.3% | |
Temperature | Principle: Thermistor method |
Range: 32 °F to 122 °F (0℃ to 50℃) | |
Resolution: 32.01 °F (0.01 ℃) | |
Accuracy: ±32.01 °F (0.1 ℃) | |
pH sensor | Principle: Glass electrode method |
Range: 0 pH to 14Â pH | |
Resolution: 0.01Â pH | |
Accuracy: ±0.1 pH | |
ORP Sensor | Principle: Glass electrode method |
Range: -1000 mVÂ to 1000 mV | |
Resolution: 0.01 mV | |
Accuracy: ±0.1 mV | |
Conductivity sensor | Principle: A pair of platinum gauze electrode |
Range:1 us/cm to 2000Â us/cm(K=1)
100 us/cm to 100 ms/cm(K=10.0) |
|
Resolution: 0.1 us/cm to 0.01 ms/cm | |
Accuracy: ±3% | |
Turbidity sensor | Principle: Light scattering method |
Range: 0 NTU to 1000 NTU | |
Resolution: 0.1 NTU | |
Accuracy: ± 5% | |
DOÂ Probe | Principle: Fluorescence |
Range:0Â mg/L to 20Â mg/L
0 ppm to 20Â ppm 0% to 200% |
|
Resolution: 0.1%/0.01 mg/L | |
Accuracy:<8mg/L: ±0.1mg/L
>8mg/L: ±0.2mg/L |
|
Blue-green algae sensor | Principle: Fluorescence |
Range: 100 celss/mL to 300,000 cells/mL | |
Resolution: 20Â cells/mL | |
Accuracy: ±5% |