GAOTek Partial Discharge Tester

GAOTek Partial Discharge Tester can be widely used in partial discharge detection of power system, including high voltage switchgear, ring network cabinet, voltage or current transformer, transformer (including dry type transformer), GIS, overhead line, cable and other equipment insulation state detection, through the following indicators to measure the discharge degree of electrical equipment: Partial discharge intensity detection: by measuring the discharge signal in one power frequency cycle, the partial discharge intensity is characterized according to the maximum value (dB) in the discharge pulse sequence.

 

GAOTek- OET-128

Description

Overview

GAOTek Partial Discharge Tester can be widely used in partial discharge detection of power system, including high voltage switchgear, ring network cabinet, voltage or current transformer, transformer (including dry type transformer), GIS, overhead line, cable and other equipment insulation state detection, through the following indicators to measure the discharge degree of electrical equipment: Partial discharge intensity detection: by measuring the discharge signal in one power frequency cycle, the partial discharge intensity is characterized according to the maximum value (dB) in the discharge pulse sequence.

 

Features

  • Detect partial discharge in high-voltage equipment with various sensors
  • Provides waveform, PRPD, PRPS, and other discharge pattern analysis
  • User-friendly interface for device data management
  • Built-in ultrasonic and TEV sensors, compatible with various sensors
  • Non-intrusive detection, no need for power-off or extra high-voltage source
  • Wide test bandwidth from 30 kHz to 2.0 GHz for different frequency bands

 

Technical Specification

TEV measurement AE measurement
Measuring range 0 dB mV to 60 dB mV Measuring range -6 dB μV to 68 dB μV
Resolution 1 dB Resolution 1 dB
Precision ± 1 dB Precision ± 1 dB
Maximum pulse per cycle 1400 Frequency Range 20 kHz to 200 kHz
Measurement frequency band 3 MHz to 100 MHz
AA measurement UHF measurement
Measuring range -6 dBμV to 68 dBμV Detection frequency 300 MHz to 2000 MHz
Resolution 1 dB Measuring range 0 dBmV to 60 dBmV
Precision ± 1 dB Sensitivity < 1 dBm
Sensor center frequency 40 kHz Sensor frequency band 300 MHz to 2000 MHz
HFCT measurement
Sensor transmission impedance 5 mV/mA
Detection frequency 1 MHz to 30 MHz
Sensitivity ≤ 50 pC
Hardware
Shell ABS
Screen 4.0 in (10.16 cm) RGB LCD screen, resolution 800 × 480
Sampling accuracy 12 bits
Synchronization mode Internal synchronization, external synchronization
Connector USB interface (also charger input)
0.14 in (3.5 mm) stereo headphone jack
External sensor input interface
Wi-Fi
Earphone 8 Ω minimum
SD card Standard configuration 16 G to 64 G
Built-in battery 3.7 V or 5000 mAh lithium battery
Operating hours Approximately 6 hrs
Charger AC 90 V to 264 V or DC 5 V
Operating temperature -4 °F to 122 °F (-20 °C to 50 °C)
Humidity 20 % to 85 % relative humidity
Volume 8.26 in × 3.93 in × 1.37 in (210 mm × 100 mm × 35 mm) 
Weight 0.88 lb (400 g) 