Description
Overview
GAOTek graphical results display optic fiber wire optical cable identifier are based on the elastic effect of optical fiber, and converts the bending or shaking signal of optical cable into visual and audio signal through coherent demodulation of light, so as to accurately find and identify the target optical cable laid in the environment of man shaft, tunnel, pipeline and over-head pole. It is a new type of nondestructive identification technology for optical cable, which has friendly interface, simple and practical, non-toxic and harmless, and no damage Optical cable and other advantages. When the target cable is bent or shaken, the OCID can quickly capture the vibration signal and display it through the waveform and sound, so as to quickly locate the target optical cable. It provides the simplest method for the telecommunication engineers and technicians to track and identify the target optical fiber or optical cable clearly.
Features
- The end is breaking point, APC or UPC can be tested
- Integrated OTDR, one machine, two tests
- No need to loop back at the far end
- No complicated parameter setting, one key test
- Link detection, graphical results display
- Target is located through audio or visual signals
- Integrated VFL/LS/OPM/Event Map/Loss Test/End Face Identifier
Technical Specifications
OCID | |
Wavelength | 1550 nm to ±20 nm |
Test Distance | 393701 ft (120 km) |
Unidirectional Optical Cable Loss | 24 dB |
Connector | APC (Interchangeable FC, SC, ST) |
OTDR | |
Wavelength | 1550 nm to ±20 nm |
Event Blind Zone | 1 m |
ATT Blind Zone | 6 m |
Loss Accuracy | 土0.05 dB/dB |
Sample Points | 16 k to 128 k |
Sample Resolution | 0.05 m to 16 m |
Reflection Accuracy | ± 3 dB |
File Format | SOR Standard File Format |
Loss Analysis | 4-pointmethod / 5-point method |
Laser Safety Level | Class â…¡ |
Refresh Rate | 3 Hz |
Data Storage | Internal storage: ≤3000 curves; External storage: 4 Gbit |
Connector | FC/UPC (Interchangeable SC, ST) |
Data Interface | USB, Mini-USB,10 M /100 M Ethernet Port |
Wavelength Range | 800 nm to 1700 nm |
Connector | Universal FC/SC/ST |
Test Scope | -50 dBm to +26 dBm |
Uncertainty | ± 5% |
Calibration Wavelength | 850 nm / 980 nm / 1300 nm / 1310 nm / 1490 nm / 1550 nm / 1625 nm / 1650 nm |
VFL | |
Wavelength | 650 nm to ±20 nm |
Output Power | ≥10 mW |
Mode | CW/1 Hz/2 Hz |
Connector | FC/UPC (Interchangeable SC, ST) |
Display | 5.6-inch color LCD + touch screen |
Power Supply | AC/DC adapter
Input: 100 V to 240 V,50/60 Hz,0.6 A Output: 12 V to 19 V,1.5 A Lithium battery: 7.4 V,5000 mAh |
Working Temperature | 14 °F to 122 °F (-10 ℃ to +50 ℃) |
Storage Temperature | -40 °F to 158 °F (-40 ℃ to +70 ℃) |
Relative Humidity | 0 to 95%, non-Condensing |
Weight | 3.30 lb. (1.5 kg) |
Size | 893 in x 6.29 in x 2.75 in (227 mm × 160 mm × 70 mm) |