Description
Technical Specifications
Maximum voltage | 30 V |
Working altitude | 1.24 mi (2 km) |
Storage altitude | 7.45 mi (12 km) |
Drop test requirements | 3.28 ft (1 m) |
Power supply | 4 x 5-gauge batteries |
Range | 0 mA to 24 mA |
Resolution | 0.001 mA |
Accuracy | 0.01% + 2 μA |
Range | 0 mA to 24 mA |
Resolution | 0.001 mA |
Accuracy (Percentage of Reading + Count) | 0.01% + 2 μA |
Temperature coefficient | ± (0.002% of reading + 0.002% of range) / °C <64.4 °F or >82.4 °F (<18 °C or >28 °C) |
Range | -10 mV to 75 mV |
Resolution | 0.01 mV |
Accuracy (Percentage of Reading, Count) | 0.015%,10 μA |
Temperature coefficient | ± (0.002% of reading + 0.002% of range) / °C <64.4 °F or >82.4 °F (<18 °C or >28 °C) |
Open-circuit voltage | 24 V ±10% |
Load circuit voltage | 18 V min. at 20 mA |
Temperature coefficient | ± (0.002 % of reading + 0.002 % of range)/°C <64.4 °F or >82.4 °F (<18 °C or >28 °C) |
Relative humidity | 90% 50 °F to 86 °F (10 °C to 30 °C) 75% 86 °f to 104 °F (30 °C to 40 °C) 45% 104 °f to 122 °F (40 °C to 50 °C) non-condensing |
Operating temperature | 14 °F to 122 °F (-10 °C to 50 °C) |
Storage temperature | -22 °F to 140 °F (-30 °C to 60 °C) |
Dimensions | 2.06 in x 3.30 in x 7.42 in (52.5 mm x 84 mm x 188.5 mm) |
Weight | 1.13 lb (515 g) |