GAOTek Portable Battery Conductance Tester is a multi-function and portable digital data storage measurement instrument. It can display and record many key parameters for multi-groups like battery string and each battery cell’s Voltage, conductance, connecting strip resistance, battery’s internal resistance and so on; offer the ability to distinguish the battery’s condition effecti Vely and accurately; compose with intelligent PC measurement analyzing software, user can track the battery’s decay trend, and alarm beforehand to help technician and administrators process according to status.
Features
- High precision online testing, automatically switches the testing range
- Transmits the test data to a PC Via Micro SD card
- Powerful data management
- Over current and Voltage protection
- Uses a SOC chip to impro Ve the tester stability
- Contrasting analysis for each battery cell within the same battery
- Large data storage capacity: at least 99,999 groups of test result
- 4 inches, 320 × 240 large LCD display
- Powered with a high capacity Lithium cell or through an adapter
- Low battery Voltage warning
- Save manpower: automatically test and store results in 3~5 seconds
Functions:
- Test the battery Voltage and conductance online
- Battery conductance and Voltage out of range alarm
- All the battery parameters are marked by the group No to make the user manage the data expediently
- PC software analyzes the battery to carry out tracking ‘ historical analysis’ of the battery system.
Technical Specifications
Model | A0110009A | A0110009B |
Conductance Test Range | 100 S-19990 S | 100 S-19990 S |
Voltage Test Range | 0.000 V to 20.000 V conductance& Voltage 20.000 V to 25.000 V Voltage only |
0.000 V to 16.000 V conductance& Voltage |
Measurement Precision | Conductance: ±0.5%rdg±6dgt Voltage: ±0.2%rdg± 6dgt |
Conductance: ±0.5%rdg±6dgt Voltage: ±0.2%rdg± 6dgt |
Power Supply | 10.8 V, 2000 mAh, Rechargeable Lithium Battery | |
Power Consumption | Work for 8 hours continuously | |
Storage Capacity | 2G SD | |
Display | 4 in, 320 × 240 matrix dot LCD | |
Size | 8.26 in x 5.5 in x 2.36 in (210 mm × 140 mm × 60 mm) | |
Weight | 2.64 lbs (1.2 kg) | |
Working Temperature | 23 °F to 140 °F (-5 °C to 60 °C) | |
Humidity | 90% RH |
Additional Information
Operating Instructions
- Boot-start
Press the Power switch for a little long time, it will display as follows:
Main menu
To operate follow the below instructions:
- Parameters setup – It can set the parameter for battery pack and start to test.
- Test batteries- Instrument will finish the last half-finished testing.
- Data management – It can View, search and delete the results.
- Config setup – It includes “Mode, Date & Time, Alarm, Backlight time, Format Memory, Query”.
Testing Operation
- Parameter setup
Choose the setup parameter in the main menu,
Press OK to enter the setup parameter face.
Parameter Setup
- Setup parameter in new battery bank menu. Choose New, and press OK enter the parameter setup face
Setup parameter interface
If you are doing a first time, to test the battery pack, please set the Value in RoomNo, StrNo, you can query the test result according to the RoomNo and StrNo, and then set the other data, if you don’t set the data, the tester will use the default parameter when it is testing.
- Set the CellNum(the cell numbers in the battery bank) – The default of cell numbers is 24 in the battery pack, you can set cell numbers in MAX.500.
- Set the UCellLow (Voltage low limited) range:
2 V:1.000~2.750 V default 2.1 V | 10 V:5.000~13.800 V default 10.5 V |
4 V:2.000~5.500 V default 4.2 V | 12 V:6.000~16.500 V default 12.6 V |
6 V:3.000~8.250 V default 6.3 V | 14 V:7.000~19.250 V default 14.7 V |
8 V:4.000~11.00 V default 8.4 V | 16 V:8.000~22.000 V default 16.8 V |
- Test Plan – Press “” and choose “ Voltage only”, “ Volts then conductance”, “ Volt & conductance”.
Note: if you don’t want to affect the Voltage testing when you test the conductance Value, please choose “ Volts then conductance”. When all Voltage testing are finished, please connect the tester and the first cell of battery pack to finish conductance testing.
- Set Parameters in menu of primary battery pack
History test results are stored in the SD card (latest 200 results). If you want to modify the parameters, choose Open and press OK, then choose battery numbers and press OK, then modify parameters and press OK to enter testing.
Set the primary battery pack data
- Connection Instruction
- Confirm the Test Mode – Before connecting battery and batteries, please confirm the Test Mode, in order to ensure test going well. Press “” and choose “test on the poles” or “add connectors testing”.
Before it is goes to testing a battery bank, it has to finish all testing of poles and connectors of one battery, then start to testing next battery. It can test different poles of a battery in any direction, but please ensure directions of e Very battery are same. When you have finished pole testing of a battery, choose “add connectors, testing”, and then start to test pole of next battery.
- Test on the poles
Cable to cell battery poles
- Add Connectors Testing (testing on the poles, and then test the connectors.)
Before you choose “add connectors testing”, please add a line. When you have finished pole testing of one battery, please connect as below picture.
Cable to cell battery connector
Below picture shows the connecting order of poles and connectors testing:
Battery bank testing steps:
First, test the poles, and then test the connectors. When finished testing of all poles and connectors of one battery, test the next cell battery poles and connectors as the same direction.
- Test battery
Choose Test in main menu, the instrument will continue to finish the testing, which it didn’t finish last time. If the tester is never set, the tester will be alarmed. If you want to set and test the stored cell battery, please choose parameter test in main menu, and press OK, enter primary battery pack and press OK to set parameters.
If you want to retest the cell battery in the testing process, press key number“2” (retest), tester will test the battery data and replace the last test result.
Data management
- Query results
Choose Data management in main menu, and press OK to enter results query interface.
Choose the data you want to query, and press OK to read.
Result query interface
- Test Mode: Poles only
Battery Information Interface 1
Press OK to View cell battery details, if you want to reset contain cell battery, press number key “2”to start retesting.
Battery Information Interface 2
Press ““▲▼” to View every cell battery details.
- Test Mode: Pole & Connector
Battery Information Interface 3
- Data Delete
Choose the test result you want to delete, press “3” to delete.
Confirms to delete the test result
Press OK to confirm deletes the data.
Note: Please confirm that the testing record is exported and saved before you delete the data.
- Test Result Export
All data stored in the SD card, Users need to insert MicroSD memory card into the card reader, and upload data to the computers through the USB port.
System management
- Mode
Choose Utilities Setup in main menu, press OK enter the interface.
Choose Mode, press OK to confirm, press C to cancel (back).
Selects the testing mode
Manual: This mode is default. In this mode, the user must press OK to start to test e Very time.
Auto: The tester will test the battery automatically according to the setting data when the testing cable connects to the battery.
- Date&Time
Choose Utilities Setup in main menu, press OK enter the interface.
Choose Date&Time and press OK.
Date&Time setting interface
Press numerical key to input the YY-MM-DD, press “tu” to move the cursor, press OK to confirm, press C to back.
- Alarm
Choose Utilities Setup in main menu, press OK enter the interface.
Choose Alarm and press OK to enter the setting interface, you can turn on/off the alarm.
Alarm setting
Press tu to move the cursor, press OK to confirm, press C to back
- Backlight time
Choose Utilities Setup in main menu, press OK enter the interface, choose Backlight time and press OK to enter the setting interface.
Backlight Time Setting.
Press tu to adjust lighting time from 0 second to 30 seconds, press OK to confirm, press C to back.
- Query
Choose Utilities Setup in main menu, press OK enter the interface, choose Query and press OK to enter the query interface.
Query
Standard Accessories
It is only for reference. The actual accessories and quantity are according to demand.
No. | Items | Qty |
1 | Battery Conductance Tester | 1 unit |
2 | Operation Manual | 1 unit |
3 | Product Certification | 1 unit |
4 | Packing list | 1 unit |
5 | Rechargeable battery | 1 unit |
6 | Power supply adapter | 1 unit |
7 | Measuring line | 1 unit |
8 | CD | 1 unit |
9 | SD Card | 1 unit |
10 | SD Card Reader | 1 unit |
11 | Carry bag | 1 unit |
Applications
- Telecommunication central office, data processing center and remote site
- Power Station, Power Plant, Switchgear, UPS
- Hospitals, utilities, mining, transportation, industrial manufacturing
- Battery Manufacturers and Ser Vers