Description
Key Features
- Large backlit high-resolution display
- Chinese graphical interface
- Accurate detection of cable (cable) routes to
- Measurement cable (optical) depth of the buried
- Current detection signal cable
- Skin damage or shield ground faults
- Detecting short circuit overhead line
- Touch the ground fault
- Determine the wet part
- The cable to Positioning Indicator cable
Â
Technical Specifications
Operating Temperature | -4 °F to 122 °F (-20 °C to 50 °C) |
Storage Temperature | -40 °F to 158 °F (-40 °C to 70 °C) |
Frequencies | Active: 577 kHz, 8 kHz, 33 kHz, 133 kHz |
Trace Mode | Passive: Power -50 Hz or 60 Hz, user-selectable; VLF -22 kHz |
Tone Mode | 577 KHz and 133 kHz pulsed at 8 Hz |
Depth | Range: 0 ft to 14.7 ft (0 m to 4.5 m) Accuracy: ±10% +1 digit for 0 ft to 4.9 ft (0 m to 1.5 m) ±15% for 4.9 ft to 14.7 ft (1.5 m to 4.5 m) |
Power | Six alkaline LR6 (“AA”) cells |
Typical Battery Life | 50 hrs |
Output Frequencies | 577 Hz, 8 kHz, 33 kHz, 133 kHz |
Trace Mode | 4 Hz or 8 Hz for sheath fault; 577 Hz and 33 kHz for tracing |
Sheath Fault Mode | 577 Hz and 133 kHz pulsed at 8 kHz |
Induction Mode | 133 kHz |
Tone Mode | 133 kHz |
Output Voltage (Maximum) | 30 Vrms |
Sheath Fault | 30 Vrms |
Trace | Normal setting: 10 Vrms |
Tone | High setting: 30 Vrms |
Output Power | Normal setting: Limited to 0.5 W High setting: Limited to 5 W |
Power | Six alkaline LR14 (C) cells |
Output Protection | 240 Vrms |
Typical Battery Life | Normal output level: 50 hrs High output level: 10 hrs |
Size | 6.75 in x 11.25 in x 7.75 in (17.2 cm x 28.6 cm x 19.7 cm) 25.5 in x 3.75 in x 10.75 in (64.8 cm x 9.5 cm x 27.3 cm) |
Weight | 5.88 lb (2.4 kg) |
Transmitter | 3.98 lb (1.8 kg) |
Receiver | 20.59 lb (9.3 kg) |