Description
Overview
GAOTek vector network analyzer is applicable to fields of radio communications, cable TV, teaching and automotive electronics etc. It can be used for performance measurement of RF components such as filter, amplifier, antenna, cable, and cable television sub connectors etc. It adopts Windows operating system, and has functions of error calibration, time domain and fixture simulator; It supports multiple display formats such as logarithmic amplitude, linear amplitude, standing wave, phase, group delay, Smith chart and polar coordinates etc.; It provides multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port, rapid SOLT calibration and electrical calibration; It is capable of multi-channel and multi-window display; It is designed with USB interface, LAN interface, GPIB interface and VGA interface. It can rapidly and accurately measure the amplitude, phase and group delay characteristics of the DUT S-parameter, with efficient and powerful error correction capability.
Features
- Dynamic range up to 125 dB
- accurate measurement on high rejection ratio devices
- 75Ω test port impedance option for cable TV components
- 001 dBrms trace noise
- network analyzer with higher measuring accuracy
- Up to 64 independent measuring channels
- can implement complex testing schemes rapidly
- AV3656 A or B100 kHz to 3 GHz 100 kHz to 8.5 GHz Network Analyzer
- Powerful data analysis functions, such as ripple test
- bandwidth test and limit test
- convenient for user to judge the conformity
- improves the test efficiency
- 4-port extension option to work together with
- 4-port extension equipment
- can test the whole 16 parameters of 4-port network
- capable of balanced parameter test
- Time domain analysis function as the standard configuration
- can simulate various R&D situations rapidly get the real-time test results
- LAN and GPIB interface
- capable of remote control and system interconnection
- 4 USB interfaces
Technical Specifications
Test points | 1 to 16001 |
IF bandwidth | Min.1 Hz; Max.5 MHz, in 1, 2, 3, 5, 7 step |
Number of test ports | 2 |
Number of test receivers | 4 |
Reference level amplitude setting | Setting range: ± 500 dB. Setting resolution: 0.001 dB |
Reference phase setting | Setting range: ± 500°. Setting resolution: 0.01° |
Time-base reference output | Output frequency: 10 MHz. Output level: +10 dBm ± 4 dB |
Digital interface | GP-IB, USB, Ethernet interface and VGA display interface |
Operation system | Windows XP |
Frequency accuracy | ± 5 × 10 to 6, 73.4 ℉ to 37.4 ℉ (23 ℃ to 3 ℃) |
Frequency range | 100 kHz to 3 GHz, 100 kHz to 8.5 GHz |
Output power setting range | -15 dBm to +10 dBm |
Channel flatness | ±2.50 dB |
The initial port directivity | Â 100 kHz to 10 MHz, 10 dB, 10 MHz to 3 GHz, 15dB, 100 kHz to 10 MH, 10 dB, 10 MHz to 3 GHz, 15 dB, 3 GHz to 6 GHz, 13 dB, 6 GHz to 8.5 GHz, 12 dB |
Port VSWR | 2.0 |
Port isolation | 100 kHz to 20 MHz, 105 dB, 20 MHz to 3 GHz, 115 dB, 100 kHz to 20 MHz, 105 dB, 20MHz to 8.5GHz, 115 dB |
Port connector type | N type (female) 50-ohm system impedance |
Number of test ports | 4 |
Power consumption | 150 W |
Power input form | 50 Hz single phase 220 V or 50Hz/60Hz single phase 110 V AC |
Display | 10.4 in (26.4 cm) high brightness LCD |
Dimensions | 17.1 in x 4 in x 14.3 in (435 mm x 102 mm x 364 mm) (including foot pad, foot, lateral stripping, input and output port) |
Weight | 17.6 lb (8 kg) |