Description
Overview
GAOTek signal analysis spectrum analyzer and signal source designed to display the signal spectrum from 35 MHz to 6200 MHz the analyzer finds the amplitude and frequency of the spectral components of the analyzed process. The spectrum analyzer can process signals from all widely used technologies: Wi-Fi, 2G, 3G, 4G, LTE, CDMA, DCS, GSM, GPRS, GLONASS, etc. Another important feature is its tracking generator, which makes it possible to measure the frequency response of passive or active devices (such as filters or amplifiers). The software allows measurement of SWR and return loss modules. This requires an external directional coupler and a set of calibration measures. It is mainly used for on-site operation. The equipment is sturdy and durable, light in weight, and low in energy consumption. It enables service centers and maintenance teams to perform on-site HF analysis for commissioning and repair work. In addition, spectrum analyzer is the perfect solution for repair shops and radio enthusiasts.
Features
- (8.12 cm) 3.2 in color resistive touch screen
- 35 MHz to 6200 MHz frequency range
- 500 points per sweep
- 2 dB accuracy in 70 dB to 75 dB dynamic range
- Windows compatibility
- PC connectivity
- Convenient use
- Compact size 5.91 in x 2.95 in x 0.91 in (150 mm x 75 mm x 23 mm)
- Lightweight 0.83 lb (380 g)
- 4 hour independent power supply
- Wired data transmission to PC
Â
Technical Specifications
Display | (8.12 in) 3.2 in color resistive touch screen |
Frequency Range | 35 MHz to 6200 MHz |
Sweep Capability | 500 points per point |
Measurement Accuracy | 2 dB within 70 dB to 75 dB dynamic range |
Display Frequency Range | 35 MHz to 6200 MHz |
Measuring Frequency Range | 35 MHz to 4500 MHz |
Dynamic Range | 75 dB |
Dynamic Range | 70 dB |
Maximum Span | 6165 MHz |
Bandwidth | 200 kHz, fixed |
Scanning Speed | 700 MHz or sec |
Sweep 100 MHz | < 0.25 seconds |
Noise Floor | < -90 dBm |
Noise Floor | < -85 dBm |
Noise Floor | < -80 dBm |
Wave Impedance | 50 ohms |
Standing Wave Ratio ( | < 1.5 |
Internal Attenuator | 0 dB to 30 dB |
Error at Attenuation up to 10 dB | 2 dB |
Attenuation Error | 5 dB |
Attenuation Error | 8 dB |
Tracking Generator Output Power | -15 dBm to -25 dBm |
Accuracy in Dynamic Range | 2.0 dB |
Maximum Input Power of Attenuator at 0 dB | 10 dBm |
Maximum Input Power when Attenuation > 20 dB | +20 dBm |
Maximum Input Measurement Signal | +10 dBm |
Maximum Input DC Voltage | 25 V |
Maximum Current Consumption | 450 mA |
Maximum Current Consumption | 500 mA |
Battery | 2500 mAh |
Duration Time | 3 hours |
Battery Charging Time | to 5 hours |
Compatibility | Windows-based computers |
PC Connectivity | Can be used with a PC |
User Convenience | Particularly convenient to use |
Power Supply | Independent power supply, up to 4 hours of operation |
Data Transmission | Wired data transmission to a PC |
Weight | 0.8 lb (380 g) |
Size | 5.9 in x 3 in x 0.9 in (150 mm x 75 mm x 23 mm) |