Description
Overview
GAOTek Ultrasonic Flaw Detector High precision Flaw Detector which is widely used in boilers, pressure vessels, electric power, petroleum, chemical industry, offshore oil, pipelines, shipbuilding, automobiles, machinery manufacturing, metallurgy, metal processing, steel structure, railway transportation, nuclear power, universe sites and other industries, it can conveniently select, locate evaluate and diagnose various defects inside the work piece.
Technical Specifications
Detection Range | 32.80 ft. (10 m) (Longitudinal wave carbon steel (Metrological performance requirements: 137.8in ≥3500 mm) |
Pulse Mode | Sharp pulse, square wave, dual-square wave |
Pulse Voltage | 100 V to 300 V adjustable |
Pulse Width | 0 ns to 500 ns continuously adjustable,10ns pace |
Damping | Strong and weak adjustable |
Pulse Repetition Frequency |
Automatic or manual, continuously adjustable from 100 Hz to 1000 Hz, with a pace of 10 Hz |
Gain | 120 dB, pace 0.1 dB, 1 dB, 10 dB |
Bandwidth | 0.1 MHz to 20 MHz |
Wave Filter | Broadband |
Display Screen | 5.0-in LCD, the effective display size is 4.25 in (108 mm) long and 2.52 in (64mm) wide |
Resolution | 800 × 480 |
Instrument Interface | Dual LEMO-00 C5 |
Alarm | Gate A, B alarm |
Output Interface | Type-c USB |
Detection Mode | Full wave, positive half wave, negative half wave, RF, envelope |
Gate | Independent A, B |
Measurement Mode | Peak, wave side |
Save Content | Single frame, multi-frame continuous recording (≤200 frames) |
Quantitative Mode | DAC curve, AVG (DGS) curve |
Auxiliary Functions | Support touch, virtual keyboard, automatic gain, peak memory, freeze |
Flaw Detection Standards |
AWS D1.1 or D1.5, NB/T 47013, GB/T 29712, GB/T 11345 |
Battery | 8 hours |
Unit | Â Metric, imperial |
Charger | AC (100 V to 240 V, 50 Hz to 60 Hz) |
Operating Temperature | 14 °F to 131 °F (-10 ℃ to 55 ℃) |
Horizontal Linearity | 0.6% (Metrological performance requirements: ≤2%) |
Vertical Linearity | 2.8% (Metrological performance requirements: ≤6%) |
Sensitivity Margin | 47 dB (Metrological performance requirements: ≥42 dB) |
Dynamic Range | 40 dB (Metrological performance requirements: ≥26 dB) |
Resolution | 36 dB (Metrological perform) |
Size | 7.20 in × 4.44 in × 1.77 in (183 mm × 113 mm × 45 mm) |
Weight | 1.49 lb. (680 g) |