Description
Overview
GAOTek building inspection system with hygrometer efficiently identifies building-related issues by combining the advantages of Infrared Guided Measurement (IGM™) and Multi-Spectral Dynamic Imaging (MSX®) with advanced environmental sensors. This all-in-one tool is accurate and easy to use, allowing you to quickly locate, clearly identify, and document problems related to moisture and building envelope issues. The integrated pinless moisture sensor provides fast, non-invasive readings. Moreover, the built-in hygrometer and the field-replaceable temperature/relative-humidity sensor expedite troubleshooting, while METERLiNK® facilitates connectivity with mobile devices, enabling data upload to the FLIR Tools® app.
Features
- Comprehensive documentation ease
- Quick and precise problem localization
- Fast and clear visualization of building issues
- Efficient and accurate diagnosis
- Time and resource efficiency
Technical Specifications
Thermal Imaging Resolution | 160 x 120 pixels (19,200 pixels) |
Spectral Response | 8 μm to 14 μm |
Field Of View | 55 ° x 43° |
Sensitivity | <70 mK |
Object Temperature Range | 32 °F to 212°F (0 °C to 100 °C) |
Image Update Speed Frequency | 9 Hz |
Thermal Image Palettes | Iron, Rainbow, Arctic, White-hot, Black-hot |
MSX® | Adds visual details to full-resolution thermal image |
Image Modes | Thermal, visual, MSX® |
Internal Memory | 8 GB |
Image Gallery | Yes |
Display Type | QVGA (320 x 240 pixels) 2.8 in (71.12 mm) colour TFT graphical display |
Pin Moisture | Range 7 % to 100 % Accuracy ±1.5 %, 7 % to 30%, Reference only 30 % to 100 %, Groups 11 material groups |
Pinless <oisture | Range and accuracy 0 % to 100 % relative, Depth maximum of 0.75 in (19 mm) |
Measurement Resolution | 0.1 |
Response Time | Pinless mode 100 ms, Pin mode 750 ms |
Relative Humidity | Range 0 % to 100 % RH Basic accuracy ±2.5 % Detailed accuracy ±4.7 % (0 % to 10% RH), ±2.5 % (10 % to 90% RH), ±4.7 % (90 % to 100% RH) |
Air Temperature | Range 32 °F to 122 °F (0 °C to 50 °C) Accuracy ±1.1 °F or ±0.6° C |
Dew Point | Range -22 °F to 122°F (-30 °C to 50°C) Basic accuracy ±1.8 °F or ±1.0 °C |
Vapor Pressure | Range 0 kPa to 12.0 kPa Basic accuracy ±0.05 kPa |
Mixing Ratio | Range: 0 to 80.0 g per kg (0 GPP to 560 GPP), Basic accuracy 0.25 g per kg (±2 GPP) |
Saved Image File Format | Radiometric jpeg |
Stored Image Capacity | 15,000 Images |
Digital Camera | 2 MP field of view: 83° (70.5° HFOV x 56° VFOV) |
Language Options | 22 |
Laser Type | Visible class 2, single laser pointer to center of thermal image |
Continuous Run Time | 16 hours maximum |
Typical Usage | 4 work weeks |
Auto Power Off | Programmable off, 1, 5, or 20 minutes |
Battery | Rechargeable 4.2 V, 5400 mAh LiPo |
Temperature | Operating -4 °F to 140 °F (-20 °C to 60 °C), Storage -4 °F to 113 °F (-20 °C to 45 °C) |
Humidity | Operating 5 % to 95 % Storage 90 % relative humidity (no condensation) |
Drop Test | 6.6 foot (2 m) |
Dimensions | 6.2 in x 3.3 in x 1.7 in (16 cm x 8.5 cm x 4.4 cm) |
Weight | 14.3 oz (406 g) |