Description
Features
- 1-5 Points calibration, auto-recognizes conductivity standards
- Automatic electrode diagnosis shows the calibration points and factors
- Selectable settings: cell constant, temp, TDS; compensations for water types
- Auto temp compensation for precise readings across the range
- Auto-Read function senses and locks the measurement endpoint
- Calibration due alarm prompts user to calibrate the meter regularly
- Auto-Power Off effectively conserves battery life
- Setup menu for customizable calibration, stability, and unit settings
- Reset function restores factory settings automatically
- Expanded memory stores or recalls up to 500 data sets
- USB communication interface is easy to transfer data to PC
- Multi-mode power scheme ensures seamless meter usage
Technical Specifications
Conductivity Measurement Range | 0.01 ms/cm to 20.00 ms/cm and 200.0 ms/cm and 2000 ms/cm and 20.00 mS/cm2 and 200 mS/cm2 |
Accuracy | ±0.5% F.S. |
Resolution | 0.001 and 0.01 and 0.1 and 1 |
Calibration Points | 1 to 5 Points |
Calibration Solution | 10 µS/cm and B4 µS/cm and 1413 µS/cm and 12.88 mS/cm and 111.8 mS/cm or User-Defined |
TDS Measurement Range | 0 ppm to 10.00 ppm and 100.0 ppm and 1000 ppm 10.00 ppt and 100 ppt (Max. 200 ppt) |
Accuracy | 1% FS |
Resolution | 0.01, 0.1, 1 |
TDS Factor | 0.01 to 1.00 (Default 0.5) |
Salinity Measurement Range | 0.00 ppt to 80.00 ppt and 0.00 psu to 42.00 psu |
Accuracy | 1% FS |
Resolution | 0.01, 0.1, 1 |
Measurement Modes | Practical Salinity (Psu) or Natural Seawater (Ppt) |
Resistivity Measurement Range | 0.00 MQ to 20 ΜΩ |
Accuracy | 1% FS |
Resolution | 0.01, 0.1, 1 |
Temperature Measurement Range | 32 °F to 221 °F (0 °C to 105 °C) |
Accuracy | 0.9 °F (0.5 °C) |
Resolution | 0.1 °F (0.1 °C) |
Calibration Points | 1 Point |
General Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic |
Cell Constant | K-0.1, 1, 10 or User-defined |
Temperature Coefficient | Linear and Pure Water Compensation |
Reference Temperature | 77 °F (25 °C), 68 °F to 77 °F (20 °C or 25 °C) |
Hold Function | Manual or Automatic Endpoint Detection |
Stability Criteria | Low or High |
Calibration Due Alaram | 1 to 31 days |
Power Off | Manual or Automatic (10 min and 20 min or 30 min After Last Key Pressed) |
Memory | Stores Up to 50 Data Sets |
Output | USB Communication Interface |
Connector | 6-pin Mini Plug |
Power Requirement | 3 V x 1.5 V AA Batteries or DC 5 V Power Adapter |
Dimension | 6.69 in × 3.34 in × 1.18 in (170 mm x 85 mm × 30 mm) |
Weight | 0.62 lb. (300 g) |