- Professional benchtop conductivity meter is equipped with a 7-inch TFT display
- 1 to 3 points calibration with automatic recognition for conductivity standards
- Cell constant, ref. temp, TDS factor, water compensation modes
- Auto temp compensation corrects conductivity to reference temperature
- Auto-Read function senses and locks the measurement endpoint
- Timed Interval Readings sends the measurement data to a PC or printer
- Limit Alarm automatically alerts when reading exceeds the specified range
- Calibration due alarm prompts user to calibrate the meter regularly
- Calibration report shows the date, time, calibration point and factor
- Password protection prevents the unauthorized calibration and settings
- Expanded memory stores or recalls up to 1000 data sets
- Reset function automatically resumes all settings back to the factory defaults
Technical Specifications
Conductivity Range | 0 µS/cm to 20.00 µS/cm and 200.0 µS/cm to 2000 µS/cm and 20.00 mS/cm and 200.0 mS/cm |
Resolution | 0.001, 0.01, 0.1, 1, Automatic |
Accuracy | ±0.5% F.S. |
Calibration Points | 1 to 3 Points |
Calibration Solutions | 10 µS or 84 µS or 1413 µS or 12.88 mS or 111.8 mS |
TDS Range | 0 mg/L to 10 mg/L and 100 mg/L and 1000 mg/L and 10.00 g/L to 200.0 g/L |
Resolution | 0.01 and 0.1 and 1 and Automatic |
Accuracy | ±1% F.S. |
TDS Conversion Factor | 0.1 to 1.0 (Default 0.5) |
Salinity Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu / 0.00 to 8.00% |
Resolution | 0.01 |
Accuracy | ±1% F.S. |
Resistivity Range | 0.00 MΩ to 30.00 MΩ |
Resolution | 0.01, 0.1, 1, Automatic |
Accuracy | ±1% F.S. |
Conductivity Ash Range | 0.00 to 100% |
Resolution | 0.01, 0.1, 1, Automatic |
Accuracy | ±1% F.S. |
Temperature Range | 32 °F to 221 °F (0 °C to 105 °C) |
Resolution | 0.1°C/°F |
Accuracy | ±0.9 °F (±0.5 °C) |
Offset Calibration | 1 Point |
Calibration Range | Reading ±10 °C/ °F |
Other Specifications Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic |
Temperature Coefficient | Linear (0.0%/°C to 10.0%/°C) / Non-Linear / Pure Water |
Reference Temperature | 68 °F or 77 °F (20 °C or 25 °C) |
Cell Constant | 2-Pole Electrodes (K=0.1 / 1 / 10) or 4-Pole Electrode |
Stability Criteria | Standard / High-accuracy |
Measurement Modes | Continuous / Auto-Read Measurement Endpoint |
Timed Interval Readings | 10 or 30 or 60 sec, 10 or 30 Minutes or Off |
Calibration Due Alarm | 1 to 31 Days or Off |
High/Low Limit Alarm | Selectable |
Password Protection | 4 Digits |
Memory | Stores Up to 1000 Data Sets |
Output | USB Communication Interface |
Connector | 6-pin Mini-DIN, 3.5 mm Jack Socket |
Display | 7-in TFT LCD |
Power Supply | 12 V DC Power Adapter |
Environmental Conditions | 32 °F to 122 °F (0 °C to 50 °C), Relative Humidity <80% |
Dimensions | 9.44 in × 8.66 in × 3.15 in (240 mm × 220 mm × 80 mm) |
Weight | 3.74 lb. (1.7 kg) |