Range |
0 in to 393.7 in (0 mm to 10000 mm), at steel velocity |
Material Velocity |
100 m/s to 20000 m/s |
Pulse Repetition Frequency |
20 Hz to 2000 Hz |
Dynamic Range |
≥38 dB |
Linearity |
Horizontal ± 0.2%, Vertical 2.0%, Amplifier Accuracy ± 1 dB |
Resolving Power |
>40 dB (5P14) |
Sensitivity Leavings |
>66 dB |
Reject (suppression) |
0% to 80% full screen height |
Test Modes |
Pulse echo, dual element and thru-transmission |
Probe Types |
Single Straight, Single Angle, Dual Straight, Dual Angle, Through, Creeping, Surface |
Gate Monitors |
Two independent gates controllable over entire sweep range |
Units |
Inch or milli meter |
Power Requirements |
AC Mains 100 V AC to 240 V AC, 50 Hz to 60 Hz |
Display Delay |
-20 µs to 3400 µs |
Probe Delay/Zero Offset |
0 µs to 99.99 µs |
H×W×D(mm) |
9.44 in × 5.9 in × 1.96 in (240 mm × 150 mm × 50 mm) |
Pulse Energy |
70 V, 100 V, 200 V, 300 V, 400 V, 500 V selectable |
Rectification |
Positive half wave, negative half wave, full wave, RF System |
Bandwidth (amplifier bandpass) |
0.2 MHz to 20 MHz |
Gate Monitors |
Two independent gates controllable over entire sweep range |
Sensitivity |
110 dB max in selectable resolution 0.1 dB, 1.0 dB, 2.0 dB, 6.0 dB |
Transducer Connections |
LEMO 01 |
Operating Temperature |
18 °F to 122 °F (-10 ℃ to 50 ℃) |
Storage Temperature |
-22 °F to 122 °F (-30 ℃ to 50 ℃) |
Weight |
3 lbs (1.4 kg) |