Description
Overview
This Conductivity TDS Meter has range of -2 pH to 20 pH, resolution of 0.1, 0.01, 0.001 pH, ±0.002 pH accuracy, and up to 6 points calibration.
Technical Specifications
Parameters | PH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal. /DO Saturation) |
Range | -2.000 pH to 20.000 pH |
Resolution | 0.1 pH, 0.01 pH, 0.001 pH |
Accuracy | ±0.002 pH |
Calibration Points | Up to 6 |
Standard Customization | Yes |
Calibration Reminder | Yes |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers |
Slope Limit | Yes |
MV/ORP | |
Range | -2000.00 mV to 2000.00 mV |
Resolution | 0.1 mV, 0.01 mV |
Accuracy | ±0.1 mV or ±0.03% of reading whichever is greater |
EH ORP Mode | Yes |
ORP Calibration Points | 1 custom point (relative mV) |
pX | |
Range | -2.000 pX to 20.000 pX |
Resolution | 0.1 pX, 0.01 pX, 0.001 pX |
Accuracy | ±0.002 pX |
Calibration Points | Up to 6 |
ISE | |
Range | 1 e-9 to 9.999 e9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm |
Resolution | Up to 4 significant digits |
Accuracy | ±0.3% |
Calibration Points | Up to 6 |
Conductivity | |
Range | 0 μS/cm to 2000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection |
Accuracy | ±0.5% FS |
Calibration Points | Up to 5 |
Calibration Reminder | Yes |
Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm |
Resistivity | |
Range | 5 Ω·cm to 100 MΩ·cm |
Resolution | 0.01 Ω·cm minimum |
Accuracy | ±0.5% FS |
TDS | |
Range | 0 ppt to 1000 ppt |
Resolution | 0.001 ppm minimum, changed with range |
Accuracy | ±0.5% FS |
Salinity | |
Type | NaCl% |
Range | 0% to 8% |
Resolution | 0.01% |
Accuracy | ±0.1% |
Dissolved Oxygen Concentration – Polarographic | |
Range | 0.00 mg/L to 99.99 mg/L |
Resolution | 0.01 mg/L |
Accuracy | ±0.3 mg/L (0 mg/L to 20 mg/L); ±10% (20.00 to 99.99 mg/L) |
Calibration Reminder | Yes |
Calibration Points | Air-saturated water or zero point |
Barometric Compensation | Yes |
Manual Salinity Factor Correction | Yes |
% Saturation -Polarography | |
Range | 0.0% to 600% |
Resolution | 0.10% |
Accuracy | ±2.0% |
Temperature | |
Unit | (°C) °F |
Resolution | 0.1 |
Accuracy | ±0.1 |
Measurement | |
Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked |
Temp. Compensation | ATC, MTC |
Data Management | |
Data Storage | 1000 Groups |
GLP Features | Yes |
Log Management | Yes |
Inputs | |
PH Electrode | BNC(Q9) |
DO With Temp. Probe | 4-pin aviation connector |
Conductivity With Temp. Probe | 5-pin aviation connector |
Outputs | |
USB | USB 2.0 flash memory device, PC |
RS 232 | printer, scanner, auto-sampler |
Display Options | |
Backlight | Yes |
Auto Shutdown | 1 min to 60 min, off |
IP Rating | IP 54 |
Date And Time | Yes |
General | |
Power | AC Adapter, 100 V to 240 V AC input, DC 24 V output |
Temperature Range | 14 °F to 275 °F (-10 °C to 135 °C) |
Conductivity Reference Temperature | 41 °F, 50 °F, 59 °F, 64.4 °F, 68 °F, and 77 °F (5 °C, 10 °C, 15 °C, 18 °C, 20 °C, and 25 °C) |
Dimensions | 8.66 in × 7.67 in × 2.67 in (220 mm × 195 mm × 68 mm) |
Weight | 2.09 lb. (950 g) |