Description
Features
- Portable, rugged, lightweight
•More accurate testing results and better repeatability
•Up to 8 fiber faults can be detected in each measurement
•Automatic Pulse Width Control design to ensure a convenient operation
•Easy to identify the fault location
•Built-in visual fault locator, conveniently to find the faults in dead zone
•Dust, water and shock proof, designed for field use
•Long battery life, up to 5000 measurements operation
Technical specification
Operating Wavelength | 1550 nm (1310 nm Optional) | |
Fiber Type | 9 um or 125 um SM Fiber | |
Optical Connector Type | FC or PC | |
Detector Type | InGaAs | |
Peak Power of laser | ≥60 mW | |
Max. Displaying Distance | Reflection Event | 37.28 mi (60 km) (≥1 dB) |
Non-reflection Event | 12.42 mi (20 km) (≥2.5 dB) | |
Reflection Event Dead Zone | 49.2 ft (15 m) | |
Distance Accuracy (Reflection Event) | ±(6.36 ft (2 m) + 2 x 10 (-4) x Distance) | |
Wavelength of VFL Option | 650 nm | |
Output Power of VFL Option | >=1 mW | |
Power Supply | Alkaline Battery (3 pcs AA 4.5 V Batteries) | |
Battery Operating Time | ≥5000 measurements | |
Working Temperature | 23 °F to 104 °F (-5 ℃ to 40 ℃) | |
Storage Temperature | 14 °F to 140 °F (-10 ℃ to 60℃) | |
Humidity | 0% to 85% (Non condensation) | |
Dimensions | 7.4 in x 3.93 in x 2 in (190 mm x 100 mm x 50 mm) | |
Weight | 0.99 lb (450 g) |