- 3.5″ backlit LCD for multiparameter water quality measurement
- 1–5-point calibrations with automatic buffer recognition
- Automatic electrode diagnosis displays pH slope and offset
- 1-point offset calibration adjusts displayed value accurately
- Relative and absolute millivolt modes for reliable ORP measurements
- 2–5-point calibrations, including 8 concentration points selection
- Direct ion concentration readout simplifies measurement
- Automatic electrode diagnosis displays calibration points and slopes
- Selectable concentration units and ionic valency for flexibility
- 1–5-point calibrations with automatic recognition for conductivity standards
Technical Specifications
Range | -2.000 pH To 20.000 pH |
Resolution | 0.001,0.01, 0.1 pH, Selectable |
Accuracy | ±0.002 pH |
Calibration Points | 1 to 5 Points |
pH Buffer Options | USA, NIST, DIN, 2 Custom Buffers |
Range | ±1999.9 mV |
Resolution | 0.1, 1 mV, Selectable |
Accuracy | ±0.2 mV |
Calibration Points | 1 Point |
Range | 0.001 to 19999 (Depending On The Range Of ISE) |
Resolution | 0.001, 0.01, 0.1,1 |
Accuracy | ±0.5% F.S. (Monovalent), ±1% F.S. (Divalent) |
Measurement Units | ppm, mg/L, mol/L, mmol/L |
Calibration Points | 2 to 5 Points (0.001,0.01, 0.1,1,10, 100,1000, 10000) |
Resolution | 0.001,0.01,0.1,1 |
Accuracy | ±0.5% F.S. |
Calibration Points | 1 to 5 Points |
Calibration Solutions | 10 pS/cm, 84 pS/cm, 1413 pS/cm, 12.88 mS/cm, 111.8 mS/cm |
Temperature Coefficient | Linear (0.0% To 10.0%/°C), Pure Water |
Reference Temperature | 68°F Or 77°F (20 °C Or 25 °C) |
Cell Constant | K=0.1,1, 10 Or Custom |
Range | 0 ppm 10.00 ppm,100.0 ppm,1000 ppm, 10.00 ppt, 200.0ppt |
Resolution | 0.01,0.1,1 |
Accuracy | ±1% F.S. |
TDS Factor | 0.1 To 1.0 (default 0.5) |
Range | 0.00 psu To 42.00 psu, 0.00 ppt To 80.00 ppt |
Resolution | 0.01 |
Accuracy | ±1% F.S. |
Range | 0.00 MQ To 20.00 MQ |
Resolution | 0.01 |
Accuracy | ±1%F.S. |
Range | 0.00 mg/L To 20.00 mg/L, 0.0% To 200.0% Saturation |
Resolution | 0.01 mg/L, 0.1% |
Accuracy | ±0.2 mg/L, ±2.0% |
Calibration Points | 1 or 2 Points |
Barometric Pressure Correction | (0.60 bar to 1.13 bar) 60.0 kPa to 112.5 kPa or 450 mmHg to 850 mmHg, Manual |
Salinity Correction | 0.0g/L to 50.0g/L, Manual |
Temperature Compensation | 32 °F To 212 °F (0 °C to 100 °C), Manual or Automatic |
Memory | 500 Data sets. USB Communication Interface |
Power Requirements | 3 x 1.5 V AA Batteries or DC 5 V Power Adapter |
Dimension | 6.69 in x 3.34 in x 1.18 in (170 mm x 85 mm x 30 mm) |
Net Weight | 0.66 lbs. (300 g) |