Description
Technical Specifications
Function | Ground resistance, Soil resistivity, DC resistance, Ground voltage, AC current |
Interference Voltage | < 20 V (should be avoided) |
Interference Current | < 2 A (should be avoided) |
Measure R Electrode Spacing | A >5d |
Measured Electrode Spacing | A >20h |
Power | 8.4 V lithium battery (built-in) |
Backlight | Controllable backlight, suitable for use in dim places |
Measurement Mode | Precise four-wire three-wire measurement, simple two-wire measurement Selection method, double clamp method for measuring grounding resistance |
Measurement Methods | 2.3.4-wire method measurement: Polarization method, measuring current 20 mA Max Soil resistivity: four-pole method Selectivity Measurement: Polarization Method, Measuring Current 20 mA Max Double clamp method: non-contact mutual inductance measurement method, test current 1 mA Max DC resistance: polarization method AC current: average rectification (clamp) Ground Voltage: Average Rectification (between S-ES interface) |
Test Voltage Waveform | Sine wave |
Test Frequency | 128 Hz |
Short Circuit Test Current | AC 20 mA max |
Open Circuit Test Voltage | AC 28 V max |
Display Mode | 4-bit large LCD display, with backlight |
Measurement Instructions | LED flashing indicator during measurement |
LCD Size | 4.3 in x 2.6 in (111 mm × 68 mm) |
LCD Display Field | 4.2 in x 2.5 in (108 mm × 65 mm) |
Instrument Size | L/W/H:10.7 in x 8.9 in x 4.5 in (277.2 mm × 227.5 mm × 153 mm) |
Clamp Size | L/T/H:3.9 in x 1 in x 8.4 in (101 mm × 27 mm × 214 mm) |
Test Line | 4 strips red 15 m, black 15 m, yellow 10 m, green 10 m each one |
Simple Test Line | 2strips:yellow 1.5 m, green 1.5 m each one |
Auxiliary Grounding Rod | 4PCS:φ 0.39 in x 7.8 in (10 mm × 200 mm) |
Current Clamp | 2 PCS: Banana plug |
Current Clamp Diameter | Φ 1.9 in (50 mm) |
Current Clamp Lead | Length 2 m |
Measure Time | AC current about 2 times/sec; Ground voltage about 2 times/sec; Grounding resistance, soil resistivity: about 7 seconds/time |
Line Voltage | Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power) |
USB Interface | With USB interface, storage data can be uploaded to the computer, save and print |
Communication Line | One USB communication line, 1.5 m long |
Data Storage | 500 groups, “MEM” storage indicates, flashing “FULL” symbol indicates that the memory is full |
Data Review | Data review function: “MR” symbol display |
Overflow Display | Over-range overflow function: “OL” symbol display |
Current clamp Low Current Indication | When measuring by the selection method or the double-clamp method, when the current signal received by the current clamp A is |
Interference Test | Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V |
Auxiliary Grounding Test | With auxiliary ground resistance test function, 0.00KΩ ~ 30 k Ω (Rh max = 3 k Ω +100R < 50 k Ω; Rs max = 3 k Ω +100R < 50 k Ω) |
Alarm Function | Alarm when the measured value exceeds the alarm setting value |
Battery Voltage | Real-time display of battery power, reminding timely charging when battery voltage is low |
Automatic Shutdown | “APO” Indicates, automatic Shutdown After 15 Minutes |
Power Consumption | Standby: 40 mA Max (Backlight off) Turn on backlight: 43mA Max Measuring:120 mA Max (Backlight off) |
Overload Protection | Grounding resistance: AC 280 V/3 seconds between H-E and S-ES ports |
Insulation Resistance | 20 M Ω (500 V between circuit and housing) |
Pressure Resistance | AC 3700 V/ rms (between circuit and housing) |
Electromagnetic Properties | IEC61326 (EMC) |
Suitable For Safety Regulations | IEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, pollution level 2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. JG 366-2004(ground resistance meter); JJG 1054-2009(Clamp grounding resistance meter). |
Ambient Temperature And Humidity | 73 ℉ ± 9 ℉ (23 ℃ ± 5 ℃), below 75% RH |
Working Temperature And Humidity | 14 ℉ to 104 ℉ (-10 ℃ to 40 ℃), below 80% RH |
Storage Temperature And Humidity | -4 ℉ to 140 ℉ (-20 ℃ to 60 ℃), below 70% RH |
Weight | Instrument: 5.3 lb (2.43 kg) (with battery) Current clamp:2 lb (0.94 kg) (2PCS) Test lines:2.8 lb (1.3 kg) (including simple test line) Auxiliary grounding rod: 1.7 lb (0.85 kg) (4PCS) |