Description
Features
- Test Condition without Shutting Down Battery
- Simultaneously Measure Battery Resistance, Voltage, Current, Temperature
- Auto-hold and Auto-data storage
- Comparator Function
- Rates Conditions as Pass, Warning, or Fail
- Memory and Read Function
- Compact and Lightweight
- RS232 PC Interface
Technical Specifications
Battery Types Tested | Compact storage batteries, Alkali and lead-acid batteries |
Battery Capacity | 0 AH to 1200 AH |
Resistance | Ranges: 4 mΩ, 40 mΩ, 400 mΩ, 4 Ω, 40 Ω, 400 Ω Resolution: 1 μΩ, 10 μΩ, 100 μΩ, 1 mΩ, 10 mΩ, 100 mΩ Accuracy: 4 mΩ ±(2% reading ±8 digits) 40 mΩ to 400 Ω ±(0.8% reading ±6 digits) |
Measurement Condition | Current: Approx. 40 mA, 4 mA, 400 μA, 40 μA, 4 μA Frequency: 1 KHz ±30 Hz |
DC Voltage | Range: 6 V, 60 V Resolution: 1 mV, 10 mV Accuracy: ±(0.1% rdg ±6 digits) |
Temperature | Range: -4 °F to 140 °F (-20 °C to 60 °C) Resolution: 0.1 or 0.1 Accuracy: ±1 or ±1.8 |
DC Current | Range: 60 A, 600 A Resolution: 0.01 A, 0.1 A Accuracy: 60A: ±(2% rdg +20 dgt), 600 A: ±(2% rdg + 2 dgt) |
Open Circuit Voltage | 5 V max |
Manual Data Memory | 999 data sets |
Continuous Data Memory | 6000 data sets (only use PC download) |
Comparator | Setting: Resistance upper and lower limits and voltage through hold limit. Memory: 99 sets of values |
Operating Environment | 0 °F to 40 °F (32 °C to 104 °C), 80% RH or less, non-condensing |
Maximum Input Voltage | 60 V DC |
Power Supply or AC Adapter | Six AA size 1.5 V alkaline batteries |
Battery Life | 5.5 hrs |
Weight | Approx. 1.16 Ib (530 g) including batteries |
Dimensions | Approx. 7.7 in x 3.7 in x 1.9 in (198 mm × 94 mm × 49 mm) |