Description
Overview
GAOTek true RMS wireless clamp meter is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, and data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9A dc or ac through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind and are also rated to CAT III 1500 V dc.
Features
- Measure safely with CAT III 1500 V rated clamp meter
- Thin jaw for access to cables in crowded combiner boxes
- Sturdy IP54 rated for outdoor use
- Work efficiently with dc power measurement, audio polarity and visual continuity
- DC power measurement, showing readings in kVA
- Audio Polarity indicator helps prevent accidental misfires
- Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
- Logging and reporting of test results via Fluke Connect software
- When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces
- The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements
Technical Specifications
AC Range | 999.9 A |
AC Resolution | 0.1 A |
AC Accuracy | 2 % + 5 digits (10 to 100 Hz) 2.5 % + 5 digits (100 to 500 Hz) |
AC Crest Factor (50/60 Hz) | 2.5 at 600 A 3 at 500 A 1.42 at 999.9 A Add 2 % for C.F. > 2 |
AC Current Range | 999.9 A 2500 A |
AC Current Resolution | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
AC Current Accuracy | 3 % RD + 5 digits (10 to 500 Hz) |
AC Current Crest Factor (50/60 Hz) | 2.5 at 1400 A 3 at 1100 A 1.42 at 2500 A Add 2 % for C.F. > 2 |
DC Current Range | 999.9 A |
DC Current Resolution | 0.1 A |
DC Current Accuracy | 2 % RD + 5 digits (when using the ZERO function to compensate for offsets) |
AC Voltage Range | 600 V 1000 V |
AC Voltage Resolution | 0.1 V (≤600 V) 1 V (≤1000 V) |
AC Voltage Accuracy | 1 % RD + 5 digits (20 to 500 Hz) |
DC Voltage Range | 600 V 1500 V |
DC Voltage Resolution | 0.1 V (≤ 600 V) 1 V (≤ 1500 V) |
DC Voltage Accuracy | 1 % RD + 5 digits |
mV DC Range | 500 mV |
mV DC Resolution | 0.1 mV |
mV DC Accuracy | 1 % RD + 5 digits |
Jaw Amps Frequency Range | 5 to 500 Hz |
Jaw Amps Frequency Resolution | 0.1 Hz |
Jaw Amps Frequency Accuracy | 0.5 % RD + 5 digits |
Jaw Amps Frequency Trigger Level | 5 to 10 Hz, ≥ 10 A 10 to 100 Hz, ≥ 5 A 100 to 500 Hz, ≥ 10 A |
Flexible Current Probe Amps Frequency Range | 5 to 500 Hz |
Flexible Current Probe Amps Frequency Resolution | 0.1 Hz |
Flexible Current Probe Amps Frequency Accuracy | 0.5 % RD + 5 digits |
Flexible Current Probe Amps Frequency Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
Voltage Frequency Range | 5 to 500 Hz |
Voltage Frequency Resolution | 0.1 Hz |
Voltage Frequency Accuracy | 0.5 % RD + 5 digits |
Voltage Frequency Trigger Level | 5 to 20 Hz, ≥ 5 V 20 to 100 Hz, ≥ 5 V 100 to 500 Hz, ≥ 10 V |
DC Power Range | 600 kVA (600 V DC range) 1500 kVA (1500 V DC range) |
DC Power Resolution | 0.1 kVA 1 kVA |
DC Power Accuracy | 2 % RD + 2 KVA 2 % RD + 20 kVA |
Resistance Range | 600 Ω 6000 Ω 60 kΩ |
Resistance Resolution | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 0.01 k Ω (≤ 60.00 kΩ) |
Resistance Accuracy | 1 % RD + 5 digits |
Capacitance Range | 100.0 μF 1000 μF |
Capacitance Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) |
Capacitance Accuracy | 1 % RD + 5 digits |
Capacitance Inrush Trigger Level | 5 A |
Environmental Specifications Temperature | Operating: 14 to 122°F (-10 to 50 °C) Storage: -40 to 140°F (-40 to 60 °C) |
Environmental Specifications Operating Humidity | Non-condensing (<10°C) ≤ 90 % RH at 50 to 86°F (10 to 30 °C) ≤ 75 % RH at 86 to 104°F (30 to 40 °C) ≤ 45 % RH at 104 to 122°F (40 to 50 °C) |
Environmental Specifications Altitude | Operating: 1.2 miles (2000 m) Storage: 7.4 miles (12000 m) |
General Specifications Maximum Voltage (Between Terminal and Earth Ground) | 1000 V AC 1500 V DC |
General Specifications Batteries | 2 AA IEC LR6 alkaline |
General Specifications Display | Dual display with backlight |
General Specifications Automatic power off | 20 minutes |