Below are general answers on how to operate, maintain, and calibrate a gas analyzer from the list of GAO Tek’s gas analyzers. To facilitate our customers to a selection of our products, we have further classified our gas analyzers by their features: benchtop, chlorine, flue, leak detection, handheld, rugged, volatile organic compound (VOC), waterproof, wired, and wireless.
We have products in stock and can ship overnight to most places in the U.S. and Canada.
If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.
Operating a Gas Analyzer:
- Power On Procedure:
- Ensure that the GAO Tek Gas Analyzer is connected to a stable power source.
- Power on the analyzer using the designated switch or button.
- Initialization:
- Allow the GAO Tek gas analyzer sufficient time to initialize and stabilize. Refer to the user manual for the recommended initialization time.
- Sample Collection:
- Connect the gas sample source to the GAO Tek gas analyzer’s inlet port.
- Adjust the sample flow rate to the analyzer’s specifications using the flow control features provided by GAO Tek.
- Setting Parameters:
- Access the menu or interface on the GAO Tek Gas Analyzer to set parameters such as gas type, measurement range, and any specific configurations required for your application.
- Start Measurement:
- Initiate the measurement process according to the GAO Tek Gas Analyzer’s operating instructions.
- Monitor the real-time readings displayed on the analyzer’s screen.
Maintaining a Gas Analyzer:
- Regular Cleaning:
- Power off the GAO Tek Gas Analyzer before cleaning.
- Use a soft, lint-free cloth to clean the external surfaces.
- Follow the maintenance guidelines provided by GAO Tek to clean internal components, ensuring accuracy and longevity.
- Filter Replacement:
- Regularly check and replace filters as recommended by GAO Tek to maintain optimal performance.
- Ensure that replacement filters meet GAO Tek’s specifications for compatibility and effectiveness.
- Calibration Check:
- Perform routine calibration checks using GAO Tek’s recommended calibration standards.
- Follow the step-by-step calibration procedures outlined in the user manual to maintain accuracy.
- Sensor Inspection:
- Inspect sensors for any signs of damage or contamination.
- Refer to GAO Tek’s guidelines for sensor maintenance and replacement, if necessary.
Calibrating a Gas Analyzer:
- Preparation:
- Ensure the GAO Tek Gas Analyzer is in a stable environment with minimal gas concentration variations.
- Use GAO Tek’s recommended calibration gases with known concentrations.
- Initiate Calibration Mode:
- Access the calibration mode on the GAO Tek Gas Analyzer as specified in the user manual.
- Calibration Gas Introduction:
- Introduce the calibration gas into the inlet port of the analyzer according to the recommended flow rates provided by GAO Tek.
- Adjust Calibration Settings:
- Follow the on-screen prompts to adjust calibration settings until the readings match the known concentrations of the calibration gas.
- Save the calibration parameters as specified by GAO Tek.
- Validation: Validate the calibration by measuring another known gas concentration to ensure accurate and reliable results.