Overview
GAOTek alarm co2 detector can be used in mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm would sound. Adopted 2.5-inch-high-definition colour screen for real-time display, adopted the gas sensors of internationally well-known brands, and the main detection principles include electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and so on. Adopted Swiss high-precision capacitive digital temperature and humidity sensors. Advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space, and the purity of the gas leakage and various high concentration Single gases with the background gas as nitrogen gas or oxygen gas. The types for detection are more than 500 types.
Features
- Rich human-machine interface
- It is possible to simultaneously detect 6 types of gases
- Function of large-capacity data storage (capacity can be customized)
- Various kinds of communication interfaces and printing functions
- High temperature gas detection (optional) The optional high temperature
- Graphical display
- Data recovery function
- It is possible to set whether to display the maximum, minimum, average value or not
- USB port with charging protection, supports hot-plugging, and displays charging status
- Uses a 6000-mA high-capacity rechargeable polymer battery for extended operation
- Supports real-time or timed detection; pump can be shut down when not in use
- Multiple alarm modes with multi-directional and three-dimensional indication
- Multiple alarm settings: low, high, interval, and weighted average alarms
- Zero-point automatic tracking; long-term use will not be affected by the zero drift
- Multi-level calibration for precise and linear measurements
Technical Specifications
Gases To Be Detected | Arbitrary combination of 6 types of gases as Toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on Optional configuration: temperature and humidity measurements |
Application Scenarios | All the cases which require the portable rapid detection of gas concentrations such as petroleum. chemical. pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on |
Detection Range | 0 ppm to 1 ppm, 10 ppm, 100 ppm, 1000 ppm, 5000 ppm, 50000 ppm, 100000 ppm, 200 mg per L, 100% LEL, 20%, 50%, 100% Vol, can be selected: and other ranges can be customized. |
Resolution | 0.01 ppm or 0.001 ppm (0 ppm to 10 ppm); 0.01 ppm (0 ppm to 100 ppm), 0.1 ppm (0 ppm to 1000 ppm), 1 ppm (0 ppm to 10000 ppm or more). 0.01 mg per L (0 mg per l to 200 mg per l), 0.1% LEL, 0.01%, 0.001% Vol |
Detection Principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
Allowable Error | ≤ 1% F. S (other precision levels can be customized) |
Linearity | ≤ 1% |
Repeatability | ≤ 1% |
Uncertainty | ≤ 1% |
Response Time | T 90 ≤ 20 seconds |
Recovery Time | ≤ 30 seconds |
Power Supply | 3 7 V DC, 6000 mA high-capacity rechargeable polymer battery |
Display Mode | 2.5 inch high-definition color screen |
Detection Mode | Built-in pump-suction type measurement. and flow rate at 500 ml per min. Calibration flow rate should be greater than 500 ml per min. three-way pipe should be connected. to ensure that the excessive gas will be discharged from the bypass |
Alarm Mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm |
Communication Interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition |
Data Storage | Standard configuration is the data storage capacity for 100.000 entries; SD card storage function is optional configuration |
Protection Level | IP67 |
Explosion-Proof type | Intrinsically safe type |
Explosion-Proof Mark | Ex ia IIC T4 Ga |
Standard Accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high grade aluminum instrument case, belt clip, humidity dust filter |
Optional Items | Temperature and humidity measurement function, 3.94 ft (1.2 m) retractable sampling handle (3.28 ft to 32.8 ft hose (1 meter hose to 10 meter hose), and the standard length is 3.28 ft (1 meter)), 15.75 in (0.4 meter) stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), external mini wireless infrared printer |
Detection Mode | Built in pump suction type measurement, and flow rate at 500 ml per min. Calibration flow rate should be greater than 500 ml per min, three-way pipe should be connected, to ensure that the excessive gas will be discharged from the bypass |
Working Environment | Temperature: -40 °F to 158 °F (-40 °C to 70 °C) Humidity: ≤ 10 % RH to 95 % RH, and built-in filters can be used in high humidity or high dust environment |
Sample Gas Temperature | -40 °F to 158 °F (-40 °C to 70 °C) and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 2372 °F (1300 °C) |
Temperature And Humidity Measurement | Optional configuration: Temperature at -40 °F to 158 °F (-40 °C to 70 °C) Accuracy level at 32.9 °F (0.5 °C) Humidity at 0 % RH to 100 % RH, precision level at 3 % RH |
Exterior Dimensions | 7.68 in × 3.03 in × 1.81 in (195 mm x 77 mm x 46 mm) |
Weight | 0.77 lb (0.35 kg) |