Description
Overview
GAOTek high quality diaphragm pressure anemometer adopts diaphragm as a sensitive element, and it could choose different materials based on different measure mediums. The pressure gauge mainly applys to measure the micropressure of gas, liquid in industry of course, especially fits to medium of corrosion and viscidity, non-solidification and non-crystal. The pointer of the instrument will make contacts turn on or cut with the contacts of the set fingr, causing the cut and turn-on of the control system for the purpose of automatic control and alarm.
Features
- Minimum pressure is down to 4 KPa
- According to different corrosion-proof reguests
- Liquid filling models can be supplied
Technical Specifications
Type | Standard type, vibration-proof type, oil filled |
Set accuracy | ± 4% |
Contact points | 1 or 2 |
Contact points materials | ≥ 110 V silver-nickel alloy, ≤ 36 V golden |
Range | Plus pressure 0 kpa to to 4 kpa to 0 to 2.5 Mpa, Minus pressure -4 kpa to to 0 kpa to -100 kpa and to 0 kpa and other compound ranges |
Working pressure | Steady 3/4 of full scale value |
Fluctuating | 2/3 of full scale value |
Short time | Full scale value |
Windows | Organic glass, Safety glass, double deck |
Case protection | Class standard type IP 54 |
Vibration-proof | IP 65 |
Maximum working voltage | 380 VAC or 220 VAC |
Maximum current | 1 A |
Contact power | 30 VA |
Liquid filling for vibration-proof type oil | Filling liquid for special instrument |
Connection | Thread connection M 20 x 1.5, or special requirement Flanged connection, by relative standards or promised special requirement |
Environment temperature | Standard type -40 ℉ to 158 ℉ (-40 ℃ to 70 ℃) |
Vibration-proof type | -4 ℉ to 140 ℉ (-20 ℃ to 60 ℃) |
Accuracy | 3.9 in (100 mm), ± 1.5%, ± 1.6% ± 2.5%, 6.3 in (160 mm), ± 1.5%, ± 1.6% |
Diameter | 3.9 in (100 mm), 6.3 in (160 mm) |