Description
Overview
Optional self-cleaning system to get accurate data for a long time. Can see and collect data in real-time used with platform software. Calibrate and record 49,000 test data (Can record 6 to 16 probes’ data at a time), can simply connected with the existing network for a simple combination Equipped with all kinds of lengths of extension cables. These cables support internal and external stretch and 20 kg of bearing.
Features
- Easily replace electrode on-site, simplifying maintenance process.
- The Power Save feature allows flexible sampling interval time settings.
- Sensor has reverse connection protection for power supply.
- RS485 A/B terminal protected when connected to power supply.
Technical Specifications
Temperature Principle | Thermistor method |
Range | 32 °F to 212 °F (0 °C to 100 °C) |
Resolution | 0.18 °F (0.1 ºC) |
Accuracy | ±0.18 °F (0.1 ºC) |
PH Sensor Principle | Glass electrode method |
Range | 0-14 pH |
Resolution | 0.01 pH |
Accuracy | ±0.1 pH |
ORP Principle | Glass electrode method |
ORP Range | Â -1000 mV to +1000 mV |
ORP Resolution | ORP 0.01 mV |
ORP Accuracy |  ±0.1 mV |
Conductivity Sensor Principle | A pair of platinum gauze electrode |
Range | 1us/cm to 2000 us/cm(K=1) 100 us/cm to 100ms/cm(K=10.0) |
Resolution | 0.1us/cm to 0.01ms/cm (Depending on the range) |
Accuracy | ±3% |
Turbidity Sensor Principle | Light Scattering Method |
Range | 0 to 1000 NTU |
Resolution | 0.1NTU |
Accuracy | ±5% |
DO Probe Principle | Fluorescence |
Range | 0 to 20 mg/L; 0 to 20 ppm; 0 to 200% |
Resolution | 0.1%/0.01mg/l |
Accuracy | ±0.1mg/L<8 mg/l ±0.2mg/L>8 mg/l |
Chlorophyll Sensor Principle | Fluorescence |
Range | 0 to 500 ug/L |
Resolution | 0.1 ug/L |
Accuracy | ±5% |
Blue-Green Algae Sensor Principle | Fluorescence |
Range | 100 to 300,000 cells/mL |
Resolution | 20 cells/mL |
Accuracy | ±5% |
Salinity Probe Principle | Converted by conductivity |
Range | 0 to 1 ppt (K=1.0) 0 ppt to 70 ppt(K=10.0) |
Resolution | 0.001 ppt to 0.01 ppt Depending on range |
Accuracy | ±3% |
Ammonia Nitrogen Sensor Principle | Ion selection |
Range | 0.1 mg / L 100 mg/L-N |
Resolution | 0.01 mg/L-N |
Accuracy | ±10% or ±2 mg/L |
Nitrate Nitrogen Sensor Principle | Ion selection |
Range | 0.1 to 100 mg/L-N |
Resolution | 0.01 mg/L-N |
Accuracy | ±10% or ±2 mg/L |
Chloride Sensor Principle | Ion selection |
Range | 0.5 to 1000 mg/L |
Resolution | 0.01 to 1 mg/L |
Accuracy | ±10% or ±2 mg/L |
Principle | Ion selection |
Range | 0.5 to 1000 mg/L |
Resolution | 0.011 mg/L |
Accuracy | ±10% or ±2 mg/L |