Description
Overview
GAOTek oil pollution degree moisture meter is an on-line oil particle counter integrated with moisture sensor. It can indicate oil contamination as well as water content in oil. GAOTek oil pollution degree moisture meter can be used to detect mineral oil or phosphoric acid ester synthetic oil, such as hydraulic oil, lubricating oil, transformer oil, turbine oil (turbine oil), gear oil, engine oil and other oil. Currently widely used in aerospace, electric power, petroleum, chemical, transportation, port, metallurgy, machinery, automobile manufacturing and other fields
Features
- High sensibility. Able to detect the particle as small as 1 μm
- Multiple standards available. NAS 1638, ISO 4406, GB, GJB
- Efficient Displayed data is to be updated every 45 sec
- Very small flow rate required
- When working online, as little as 50 ml flow rate is adequate.
- Little influence on hydraulic or lubricant circuit
- Optical fiber attached
- Data can be transferred to a PC if needed
- Able to display oil moisture in either RH or PPM
Technical Specifications
Maximum Pressure Value | 1 Mpa |
Working Power Supply | 10 V DC to 26 V DC |
Relative Humidity | 20 % to 85 % |
Moisture Resolution | Relative humidity of 0.1 % RH |
Storage Temperature | -40 °F to 185 °F (-40 °C to 85 °C) |
Temperature | -4 °F to 176°F (-20 °C to 80 °C) |
Particle Size | 2 µ m, 5 µ m, 15 µ m, 25 µ m, 50 µ m, 100 µ m |