Description
Features
- Integrated 5.7 in (14.47 cm) color TFT LCD display, key or touch dual operation
- Built-in stable light source function 1310 or 1550nm
- Built-in optical power meter test function
- Built-in visible red fault location (VFL)
- Has a unique test result self-diagnosis function
- Independent and convenient one-button automatic operation mode, real-time test function buttons
- Multi-wavelength synchronization test function
- With multiple waveforms viewing capabilities
- Link-band non-destructive testing
- With test file wireless transmission function
- Battery low voltage alarm function
- WinCE Windows operating system
- Less than 31.49 in (0.8 m) short-term event dead zone, test fiber jumper easily
Technical Specification
Optical Fiber Type | Single mode |
Central Wavelength | 1310 nm or 1550 nm |
Maximum Dynamic Range | 32 dB or 30 dB |
Event Dead Zone (m) | 3.3 ft (1 m) |
Attenuation Dead Zone | 19.7 ft (6 m) |
Optical Interface | FC or PC (Replaceable SC, ST) |
Test Range | 0.3 mi,0.6 mi,1.2 mi,2.5 mi,4.9 mi,9.9 mi,19.9 mi,39.8 mi,79.5 mi,159.3 mi (500m,1 km,2 km,4 km,8 km,16 km,32 km,64 km,128 km,256 km) |
Pulse Width | 5 ns or 10 ns or 50 ns or 160 ns or 320 ns or 500 ns or 1000 ns or 5000 ns or 10000 ns or 20000 ns |
Ranging Accuracy | ± {2.4 ft (0.75 m) + Sampling interval +0.005%× Test distance)} |
Attenuation Measurement | ±0.05 dB or dB |
Reflection Measurement | ±3 dB |
Data Storage | ≥2000 |
Communication Interface | USB, mini-USB,32.8 ft or 328.1 ft (10 m or 100 m) Ethernet |
VFL Output Power | ≥5 mW |
LS Output | ≥-5dBm |
OPM | +26 dBm to -50 dBm (Replaceable: +6 dBm to -70 dBm) |
Power Supply Mode | AC or DC Adapter:AC:100 V to 240 V,50 Hz to 60 Hz,0.6 A; Lithium battery:7.4 V 6700 mAh |
Working Temperature | 23 °F to 122 °F (-5 ℃ to 50 ℃) |
Preserve Temperature | −4 °F to 158 °F (-20 ℃ to 70 ℃) |
Relative Humidity | 0% to 95% non-condensation |
Volume | 8.9 in × 6.3 in × 2.8 in (227 mm × 160 mm × 70 mm) |
Weight | 2.4 lb (≤1.1 kg) |