Description
Overview
GAOTek Temperature Calibrator with DC Voltage (Resistance, RTD) adopts high-performance ARM microprocessor, can output DC voltage, resistance, thermocouple and RTD along with quick response and stable data. It comes with a true-color TFT-LCD display; keypad and touch screen operation. It also supports high precision measurement and is easy to operate. The calibrator boasts rapid response time, stable data and high precision measurements, deeming it one of the top temperature calibrators available. It is highly cost-effective and is suitable for lab applications.
Features
- DC voltage output
- Thermocouple output
- Resistance output
- RTD output
Technical Specifications
Functions | Features |
DCV | 100 mV,-10.00 to 110.00 mV,0.01mV,Accuracy:±0.05% Set point ±30 uV100 mV,-10.00 to 110.00 mV,0.01mV,Accuracy:±0.05% Set point ±0.3 mV |
OHM | 400 Ω,0.0 to 400.0 Ω,0.1Ω,Accuracy:±0.05% Set point ±0.2 Ω |
TC | |
T | -328 °F to 752 °F(-200 °C to 400 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C) |
K | -328 °F to 2462 °F(-200 °C to 1350 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C) |
J | -328 °F to 2192 °F(-200 °C to 1200 °C),32.18 °F(0.1 °C), Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C) |
N | -328 °F to 2372 °F(-200 °C to 1300 °C),32.18 °F(0.1 °C), Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C) |
E | -328 °F to 1832 °F(-200 °C to 1000 °C),32.18 °F(0.1 °C),Accuracy:±0.05% Set Point±2 °C (<=-100 °C) ±1°C (>-100 °C) |
S | -4 °F to 3182 °F(-20 °C to 1750 °C),33.8 °F(1 °C),Accuracy:
±0.05 % Set point ±3 °C (<=100 °C)±2 °C (>100 °C) |
R | -4 °F to 3182 °F(-20 °C to 1750 °C),33.8 °F(1 °C), Accuracy:±0.05 % Set point ±3 °C (<=100 °C)±2 °C (>100 °C) |
B | 1112 °F to 3272 °F(600 °C to 1800 °C),33.8 °F(1 °C), Accuracy:±0.05% Setpoint ±3 °C (<=400 °C to 600 °C) ±2 °C (>600 °C) |
RTD | |
PT100 | -328 °F to 752 °F(-200 °C to 400 °C),32.18 °F(0.1 °C), Accuracy:±0.05%
Set point ±0.6 °C |
CU50 | -58 °F to 302 °F(-50 °C to 150 °C),32.18 °F(0.1 °C), Accuracy:±0.05%
Set point ±0.6 °C |
Test Environment | |
Operating Temperature | 59 °F to 95 °F (15 °C to 35 °C) |
Humidity Range | 80 % RH or less |
Storage Temperature | 50 °F to 104 °F (10 °C to 40 °C) |
Humidity Range | 10 to 90 % RH |
Warm-up Time | > 60 minutes |
Calibration Time | 12 months |
General Specifications |
|
Battery Parameters | 8.4 V Li, 1400 mA rechargeable battery |
Size | 3.54 in x 7.68 in x 1.38 in (90 mm x 195 mm x 35 mm) |
Weight | Approx. 14.11 oz. (400 g) |
Power Supply | Input:100 – 240 V to 50/ 60 Hz 0.35 AOutput:9 V 1 A DC |
Display | 2.8″ true-color 16 M TFT-LCD display;Touch screen |
Interface | Mini-USB |
Others | Compatible with SCPI instruction set;Adjustable backlight; Automatic power off |