Description
Features
- One Function Key, Easily Operate
- Ideal Menu Style
- Auto Calibration: Velocity, Probe Delay, Angle/K Value
- USB for storage, plug and play: Convenient to read thickness values
- B Scan-Display Flaws Direct: Reducing analysis difficulty, missing detector
- Massive Data Memory: 200,000 values/5 minutes video
- Electronic Choice: Flaw detector together with high accurate thickness measured
- 5 Intelligent DAC curves, comply to JIS and API standard
Technical Specifications
Measurement Range | 1.0 mm to 12000 mm |
Resolution | 0.01mm(<100mm) 1mm(>100mm) |
Velocity | 500 m/s to 20000 m/s 20 fixed velocities |
Delay | -20 us to 3400us /resolution: 0.1µs |
Probe Delay | 0 us to 99us /resolution: 0.01µs |
Auto Calibration | Velocity Calibration &Probe Delay Calibration |
Linear Error | Horizontal error ≤0.1% Vertical error ≤3% |
Dynamic Range | ≥36 dB |
Working Environment | Temperature: -4 °F to 158 °F (-20℃ to 70 ℃) Humidity:5% to 90% |
Sensitivity | ≥64dB 200mm 2 flat-bottomed hole (mm) |
Dimension | 9.45 in x 7.09 in x 1.97 in (240 mm ×180 mm ×50 mm) |
Weight | 4.26 lb. (1.9 Kg) (including battery pack) |